Chapter 12

The piping and equipment between the street gas main and the gas piping system inlet, which is sinstalled by and is under the control and maintenance of the serving gas supplier, is the
Gas piping
Service piping
Gas fitting
Yard service
Listed metal appliance connector for dryers shall be
Concealed
Brass only
A max of 6 ft.
A max of 3 ft.
The maximum distance between a gas outlet for a fireplace and an approved operating valve is
3 ft.
4 ft.
6 ft.
15 ft.
Bushings in gas piping shall not be used in
Exterior locations
Exposed locations
Open carports
Concealed locations
Leaks in gas piping shall be located by applying:
Water into the piping
Acid to the piping
Soapy water to the exteriror of the piping
A flame
Appliance connectors shall at no time have a diameter less than
3/4 in
3/8 in
The appliance inlet connection
Pipe diameter squared
All exposed gas piping shall be kept
At least 6 in. Above grade
In a readily accessible location
In weather protected areas
In recessed or channels
Non-metallic underground gas piping shall be buried
Below the freeze line
At least twice the pipe diameter
At least 12 in. deep
At least 18 in. deep
The fitting that shall be used in lieu of the union that is not used at the appliance or outside at the meter is called a
Right and left nipple and coupling
Right and left nipple and tee
Right and left nipple and ell
Universal joint
A number 10 copper tracer wire or other approved material shall be installed with underground
Metallic gas piping
Non-metallic gas piping
Ferrous gas piping
Wrapped gas piping
When a metallic riser connects underground to poly piping, the underground horizontal metallic portion of the riser shall extend at least ___ inches before connecting to the poly pipe.
12
24
30
36
No part of a gas appliance connector shall be concealed within or extended through any
Wall or floor
Partition
Appliance housing
All of the above
Gas piping may be installed under a building or structure if the
Pipe has a protected covering
Pipe is installed in a gastight conduit
Pipe is PVC
Pipe is a continuous piece of tubing without joints or fittings
Using the table below, what is the Btu/h rating for a 40 allon water heater?
10,000
25,000
40,000
50,000
Using the table below, what is the total Btu/h rating for a domestic clothes dryer, a domestic recessed top burner section and a residential fireplace log lighter?
75,000
90,000
100,000
200,000
{"name":"Chapter 12", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"The piping and equipment between the street gas main and the gas piping system inlet, which is sinstalled by and is under the control and maintenance of the serving gas supplier, is the, Listed metal appliance connector for dryers shall be, The maximum distance between a gas outlet for a fireplace and an approved operating valve is","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}