Reviewer Quiz - Warehouse

Your Name:
Which of the following is considered an "Powered Industrial Truck"? (Choose all that apply)
0%
0
 
0%
0
 
0%
0
 
0%
0
 
0%
0
 
0%
0
 
0%
0
 
0%
0
None of the Above
How high can wood pallet storage be stacked indoors?
6 Feet
8 Feet
10 Pallets
20 Feet
Depends on the type of sprinkler system.
There is no limit as long as they are stable.
Which class of material is being stored?
Class I - Non-combustible
Class II - Non-combustible in slatted wood crates/combustible packaging
Class III - Ordinary combustibles or Group C plastics
Class IV - Group A or B plastics
All of the above.
None of the above.
Which class of material is being stored?
Class I - Non-combustible
Class II - Non-combustible in slatted wood crates/combustible packaging
Class III - Ordinary combustibles or Group C plastics
Class IV - Group A or B plastics
All of the above.
None of the above.
Which class of material is being stored?
Class I - Non-combustible
Class II - Non-combustible in slatted wood crates/combustible packaging
Class III - Ordinary combustibles or Group C plastics
Class IV - Group A or B plastics
All of the above.
None of the above.
This propane storage is acceptable?
True
False
Which part(s) of NPFA covers warehouse occupancies?
NFPA 30 Chapter 27
NFPA 101 Chapter 42
NFPA 13
NFPA 70E
All of the above.
None of the above.
This picture warrants a recommendation?
Which Recommendation best fits the deficiency?
Idle pallets should be shrink wrapped together to prevent the stack from tipping over.
Idle pallets should not be stacked more than 8 high.
Idle wood pallets shall not be stored in racks unless they are protected in accordance with NFPA 13 Chapter 12.12. Idle pallets should be moved outside or an in-rack sprinkler system should be installed.
Rack shelves should be constructed of solid metal sheets to slow the upward spread of fire.
None of the above.
All of the above.
This picture warrants a recommendation?
Which Recommendation best fits the deficiency?
Protective barriers should be installed to protect the rack posts from vehicle contact.
A UL Listed central reporting fire detection system should be installed to protect all areas of the building with smoke, heat, or combination smoke / heat detectors.
Rack shelves should be constructed of solid metal sheets to slow the upward spread of fire.
Rack should be anchored to the ground/roof/wall to prevent tipping.
None of the above.
All of the above.
{"name":"Reviewer Quiz - Warehouse", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Your Name:, 1. What type of wiring is this? (Select all that apply), What type of wiring is this? (Select all that apply)","img":"https://cdn.poll-maker.com/27-1008895/rusting-electrical-panel-00229466-7.jpg?sz=1200"}
Powered by: Quiz Maker