Practice Test 1

The____may require the submission of plans, specifications, drawings, and such other information as they may deem necessary prior to the commencement of work regulated by this code.
Plumbing Inspector
Building Authority
Authority Having Jurisdiction
Building Official
The plumbing and drainage system of any premises under the jurisdiction of the Authority Having Jurisdiction shall be maintained in a sanitary and safe operating condition by the _____
City
Plumbing Inspector
Owner or owner's agent
Building department
It Shall be the duty of the ____ to make sure that the work will stand the test prescribed before giving the notification for inspection to the Authority Having Jurisdiction
Owner
General Contractor
Plumber Doing the Work
Non-corrosive Material
A room equipped with a shower or bathtub is a _____
Toilet room
Bathroom
Shower Room
Washroom
By code definition, a stack is always ______
Straight
Horizontal
Vertical
Exposed
A device installed in a drainage system to prevent reverse flow is a _____
Sewage Ejector
Check Valve
Backwater Valve
Backflow Preventer
Disposal of sewage, or other liquid wastes, shall be by means of ______
Chemical Tank
Sewage-retaining Tanks
The Drainage System of the Building of Premises
Glass Piping
All trenches deeper than the footing of any building or structure and paralleling the same shall be at least _____
45 degrees there from
90 degrees there from
4 feet there from
12 feet there from
Threaded pipe (I.P.S) 1 1/4 inches installed horizontally, except for gas piping, shall be supported at approximately _____
5 foot intervals
10 foot intervals
12 foot intervals
15 foot intervals
All pipe, pipe fittings, traps, fixtures, materials, and devices used in plumbing systems shall be ____
Listed or labeled by a listing agency
Approved by the Authority Having Jurisdiction
Free from defects
All of the above
Screws or bolts for securing floor-mounted fixtures shall be ____
Brass
Aluminum
Galvanized Steel
Non-Corrosive Material
Every water supply to a urnial shall be protected by an approved _____
Relief Valve
Vacuum Breaker
Metering Valve
Automatic Switch
Drinking fountains shall not be installed in _____
Public Toilet Rooms
Restaurants
Bars
Schoolyards
Water closets set side by side shall be no closer than ____
15 in. Center to center
18 in. Center to center
24 in. Center to center
30 in. Center to center
Ball cocks in water closet tanks shall be installed so that the critical level of the water inlet is above the full opening of the overflow pipe at least _____
1/2 in.
1 in.
3 in.
6 in.
A lawn sprinkler atmospheric vacuum breaker must be a minimum of ____ above the tallest sprinkler head.
1 in.
6 in.
12 in.
24 in.
PEX tubing shall not be installed within the first _____ of piping connected to a water heater.
12 in.
18 in.
24 in.
36 in.
Flexible corrugated connectors of copper or stainless steel for water heater connectors shall be limited to ____
12 in.
18 in.
24 in.
36 in.
Hard-drawn copper tubing, marked with a blue stripe, is referred to as _____
Type "K"
Type "L"
Type "M"
Type "DWV"
The distance between a water heater and the union on th ewater lines shall not be more than ____
6 in.
12 in.
18 in.
24 in.
The minimum size trap and trap arm for a bathtub is _____
1-1/2 in.
2 in.
2 1/2 in.
3 in.
Vertical drainage lines connecting with horizontal drainage lines shall enter through a ____
Wye
San Tee
Combination wye and 1/8 bend
All of the above
Clean outs shall be designed to be ____
Threaded
Gastight and watertight
Easy opening
Concealed
All indirect waste piping that requires an airgap shall discharge into the building drainage system through ____
An automatic vent
A drainage airgap of 1 inch minimum
Both B and C
Vent pipes protect fixture traps against _____
Evaporation
Siphonage
Clogging
Cross-Connections
Each vent pipe or stack shall extend through its flashing and shall terminate vertically above the roof at least
6 in.
12 in.
18 in.
24 in.
Copper tube shall not be used for ____
Chemical Wastes
Water Piping
Underground drainage piping
Aboveground drainage piping
One trap may serve a set of not more than ___ single compartment sinks.
Two
One
Three
Four
No more than ___ approved slip joint fittings(s) may be used on the outlet side of a trp
One
Two
Three
Four
Storm water shall not be drained into sewers intended for ___
A combined sewer system
Sanitary drainage system
A strom drain system
A strom sewer system
Horizontal 1 1/4 inch diameter steel gas piping shall be adequately supported at intervals not exceeding _____
6 ft.
8 ft.
10 ft.
12 ft.
Where damage is not likely to occur, underground gas piping systems shall be installed with a minimum ____of cover.
6 in.
12 in.
18 in.
24 in.
Gas meters shall not be placed ____
At the side of the house
Adjacent to a driveway
At the back of the house
At the front of the house
A gas equipment shutoff valve shall be permitted to be located _____
Under fixed appliances
Encased in a wall
Inside a decorative gas appliance
In inaccessible locations
Underground non-metallic gas piping shall be installed with a tracer wire of minimum ___
AWG 14
AWG 16
AWG 18
AWG 20
{"name":"Practice Test 1", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"The____may require the submission of plans, specifications, drawings, and such other information as they may deem necessary prior to the commencement of work regulated by this code., The plumbing and drainage system of any premises under the jurisdiction of the Authority Having Jurisdiction shall be maintained in a sanitary and safe operating condition by the _____, It Shall be the duty of the ____ to make sure that the work will stand the test prescribed before giving the notification for inspection to the Authority Having Jurisdiction","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}