Power Quality Quiz

Residential customer light flicker
Can be caused by the customer's heat pump
Can be caused by the customer's neighbor's heat pump
Can be caused by distribution voltage fluctuations
All are correct
A change in light intensity from incandescent bulbs can be perceived for voltage sags as small as....?
0.25%
5%
10%
15%
Distribution system capacitors can affect harmonics by...?
Altering the flow of harmonics on the system
Creating a resonance with system impedance
Do not affect harmonics since they are for power factor correction
Altering the flow of harmonics on the system and creating a resonance with system impedance
The objective when monitoring in response to a customer complaint is to...?
Determine the supply compatibility with customer equipment requirements
Satisfy the customer by making a power quality recording
Determine the contribution of customer loads to the voltage disturbances
Determine the supply compatibility with customer equipment requirements and determine the contribution of customer loads to the voltage disturbances
Electric system impedance
Increases fault current
Is mostly resistive
Is mostly inductive
Determines load power factor
A voltage swell is defined as...?
A short duration in RMS voltage
An over-voltage event that can damage equipment
A voltage regulation problem
A short duration in RMS voltage and an over-voltage event that can damage equipment
A voltage sag is defined as...?
A short duration drop in RMS voltage
A temporary condition that damages equipment
A voltage regulation problem
All are correct
Transformer losses increase due to harmonics because….?
Increased winding losses
Increased core losses
Customer loads are unbalanced
Increased winding losses and increased core losses
The power quality monitoring process should include...?
Setting monitoring objectives prior to recorder initialization
Inspection of voltage, current, and communication leads
Setting event trigger thresholds
All are correct
Power quality standards are...?
Law, therefore their limits must be met by customers
Law, therefore their limits must be met by utilities
Law, therefore their limits must be met by customers and utilities
Are recommended practices, not law
Voltage unbalance
Can be measured in single phase and three phase systems
Applies to three phase systems
Can be caused by unbalanced single phase loads
Applies to three phase systems and can be caused by unbalanced single phase loads
Power quality standards are developed by...?
State regulatory commissions
The federal government
Developed by people most affected by their application as a consensus of best practice
Qualified electrical engineering departments of state universities
Voltage sags
Do not damage equipment
Can cause equipment to shut down
Do not damage equipment and can cause equipment to shut down
Are only a light flicker issue
Voltage unbalance is harmful to induction motors because...?
Small voltage unbalance causes disproportionately larger unbalance of phase current
Causes a considerable increase in motor temperature
Causes a counter rotating magnetic field in the motor
All are correct
{"name":"Power Quality Quiz", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Residential customer light flicker, A change in light intensity from incandescent bulbs can be perceived for voltage sags as small as....?, Distribution system capacitors can affect harmonics by...?","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}
Powered by: Quiz Maker