October 2016 Code Quiz

A detailed illustration showing various types of cable installations and electrical connections in a modern building, highlighting safety standards and electrical codes.

October 2016 Code Quiz

Test your knowledge of network-powered broadband and electrical standards with our October 2016 Code Quiz. Whether you're an industry professional, a student, or simply looking to enhance your understanding, this quiz is designed to engage and educate.

Key Features:

  • 7 challenging multiple-choice questions
  • Focus on current electrical codes and standards
  • Immediate feedback on your answers
7 Questions2 MinutesCreated by TestingWire257
1. The point of entrance _________ of a network-powered broadband cable is the point at which the cable emerges from an external wall, from a concrete floor slab, or from a rigid metal conduit (Type RCM) or an intermediate metal conduit (Type IMC) connected by a bonding conductor or grounding electrode conductor to an electrode in accordance with 830.100(B).
A. Outside a building
B. Within a building
B. Within a building
D. None of these
The point of entrance of a CATV coaxial cable is the point _________ at which the coaxial cable emerges from an external wall, from a concrete floor slab, or from a rigid metal conduit (Type RCM) or an intermediate metal conduit (Type IMC) connected by a grounding conductor to an electrode in accordance with 830.100(B).
A. Outside a building
B. Within a building
C. On the building
D. None of these
3. The point of entrance of a communications circuit is the point __________ at which the communications cable emerges from an external wall, from a concrete floor slab, or from a rigid metal conduit (Type RCM) or an intermediate metal conduit (Type IMC) connected by a grounding conductor to an electrode.
A. Outside a building
B. Within a building
C. On the building
D. None of these
4. The point of entrance of an optical fiber installation is the point __________ at which the optical fiber cable emerges from an external wall, from a concrete floor slab, or from a rigid metal conduit or an intermediate metal conduit connected by a grounding conductor to an electrode in accordance with 770.100(B).
A. Outside a building
B. Within a building
C. On the building
D. None of these
5. The point of interconnection of the PV system power source to other sources must be marked at an accessible location at the _______ as a power source and with the rated ac output current and nominal operating ac voltage.
A. Disconnecting means
B. Array
C. Inverter
D. None of the above
6. The power source for a nonpower-limited fire alarm circuit shall not be supplied through a(n) _______.
A. Ground-fault circuit interrupter
B. Arc-fault circuit interrupter
C. Inverse time circuit breaker
D. A or B
7. The power source for a nonpower-limited fire alarm circuit shall not operate at more than ________.
A. 120V
B. 300V
C. 600V
D. 20A
{"name":"October 2016 Code Quiz", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Test your knowledge of network-powered broadband and electrical standards with our October 2016 Code Quiz. Whether you're an industry professional, a student, or simply looking to enhance your understanding, this quiz is designed to engage and educate.Key Features:7 challenging multiple-choice questionsFocus on current electrical codes and standardsImmediate feedback on your answers","img":"https:/images/course1.png"}