June 2016 Code Quiz

A visually engaging image depicting electrical wiring, raceways, and safety standards with an emphasis on the 2016 electrical code.

June 2016 Electrical Code Quiz

Test your knowledge of the June 2016 Electrical Code with this comprehensive quiz designed for professionals in the electrical field. Challenge yourself with 7 multiple-choice questions covering essential topics, from conductor sizes to mounting requirements.

Key Features:

  • Multiple-choice format for easy answering
  • Covers fundamental aspects of electrical code
  • Scores and explanations provided for each answer
7 Questions2 MinutesCreated by WiringWizard57
1. The maximum size conductors permitted in a nonmetallic surface raceway shall not be larger than that for which the wireway is designed.
A. True
B. False
2. The messenger of messenger-supported wiring shall be supported at dead ends and at intermediate locations so as to eliminate _________ on the circuit conductors.
A. Static
B. Magnetism
C. Tension
D. Induction
3. The metal mounting yoke of a replacement switch isn’t required to be connected to an equipment grounding conductor if the wiring at the existing switch doesn’t contain an equipment grounding conductor, and _________.
A. The switch faceplate is nonmetallic with nonmetallic screws
B. The replacement switch is GFCI protected
C. A or B
D. The circuit is AFCI protected
4. The minimum radius of a field bend on trade size 1¼ RMC is ________.
A. 7 in.
B. 8 in.
C. 10 in.
D. 14 in.
5. The minimum size parallel conductors permitted for elevator lighting shall be _________, provided the combined ampacity is equivalent to at least that of a 14 AWG conductor.
A. 20 AWG
B. 16 AWG
C. 14 AWG
D. 1/0 AWG
6. The minimum working space on a circuit that is 120 volts-to-ground, with exposed live parts on one side and no live or grounded parts on the other side of the working space, is ________.
A. 1 ft
B. 3 ft
C. 4 ft
D. 6 ft
7. The mobile home park secondary electrical distribution system to mobile home lots shall be ________.
A. 120/208V, single-phase
B. 120/240V, single-phase
C. A or B
D. None of these
{"name":"June 2016 Code Quiz", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Test your knowledge of the June 2016 Electrical Code with this comprehensive quiz designed for professionals in the electrical field. Challenge yourself with 7 multiple-choice questions covering essential topics, from conductor sizes to mounting requirements.Key Features:Multiple-choice format for easy answeringCovers fundamental aspects of electrical codeScores and explanations provided for each answer","img":"https:/images/course2.png"}
Powered by: Quiz Maker