WAC/RCW Quiz #11

A residential patio cover for an overhead conductor span must have at least_____________of clearance.
12"
24"
36"
48"
What is the minimum angle between the mast and the braces of the supporting wires?
30 degree
45 degree
60 degree
Except as otherwise required by the serving utility, service mast support must be installed if the service drop is greater than___________in length away from the pole or support.
50'
100'
200'
250'
Use of couplings for a mast is permitted only____________the point where the mast is braced, secured, or supported.
Above
Below
At
______________,non-hardening mastic must be placed between lead-type flashings and the conduit.
Aluminum
Plastic
Copper
Steel
An intermediate support mast must be installed in an approved manner with methods_________those required for service masts.
Identical to
Equal to
Either of the answers provided
Neither of the answers provided
What is the minimum number of hours you must have in fieldwork before taking a speialty electrician exam?
1,000
2,000
3,000
4,000
The master electrician exam will have questions relating to_____________.
Safety
The state electrical code
Electrical theory
All of the answers provided
Before installing the service and equipment, the_____________must contact the utility program regarding the service entrance requirements for meter equipment and location.
Owner
Owner's agent
Electrical contractor
Any of the answers provided
The total thickness of sheetrock required on both sides of a 2-hour firewall is__________.
1"
1 1/4"
2"
2 1/2"
Who sets the standards for the height of the center of the service meter?
The serving utility
The department
The WAC's and RCW's
The federal power administration
All overhead drops for service, feeder or branch circuits not exceeding #1 al or #3 cu must be rigid steel galvanized conduit no smaller than____________.
1"
1 1/4"
2"
2 1/2"
The service disconnecting means shall have an identification plate with____________high letters.
1/4"
1/2"
3/4"
5/8"
The minimum distance between rods when installed in cases of services feeding adjacent but structurally seperate buildings is___________.
2'
6'
10'
12'
When the sevice disconnecting means inside the building or structure, it must be located so that the service raceway extends no more than___________into the building/structure.
10'
15'
20'
30'
50'
The inspection of telephone lines along state highway right of ways are conducted by____________.
Department of transportation
Department of electrical inspection
Highway commission
Prior to completion of an exterior wall cover inspection, all wiring and device boxes must be protected by a steel plate a minimum of ____________thick and must cover the area of the wiring or box.
1/16"
1/8"
3/32"
5/32"
1/4"
{"name":"WAC\/RCW Quiz #11", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"A residential patio cover for an overhead conductor span must have at least_____________of clearance., What is the minimum angle between the mast and the braces of the supporting wires?, Except as otherwise required by the serving utility, service mast support must be installed if the service drop is greater than___________in length away from the pole or support.","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}