Lenovo Technical Sales

1. Which two statements are true regarding Lenovo XClarity Integrator? (Select two.)
It integrates with IBM Hardware Management Console.
It integrates with Citrix XenServer.
It integrates with VMware Virtual Center.
It integrates with XEN VM Server
It integrates with Microsoft Systems Center.
A customer wants to install a Windows operating system on a System x server. Which tool helps with this installation process?
ServerGuide
ThinkServer Deployment Manager
Dynamic System Analysis
Advanced Settings Utility
A customer is looking at different x86 solutions, including a UCS B-series solution. What Lenovo product should the technical specialist propose in order to offer a similar form factor?
Enterprise x6 servers
Flex System
Rack optimized 1U/2U servers
IDataPlex
Which two functions are valid for the FPC (Fan and Power Controller) in a NeXtScale node? (Select two.)
Web interface
Power on/off nodes
Ethernet passthrough to node IMM
IPMI command line
Ftp interface
Lenovo offers a number of reference architectures that can assist a client specialist with building a configuration to meet each client's requirements. What should the technical specialist use in order to obtain the reference architectures?
Top Seller
Lenovo Press
Lenovo Partner Network
Pre-Sales Adviser Tool
Which tool can be used for customizing and deploying hardware configurations on System x servers?
Lenovo Dynamic System Analysis
ThinkServer Deployment Manager
Lenovo ServerGuide Scripting Toolkit
Bootable Media Creator
What is a feature of the System x3500 M5?
Supports up to three ServeRAID M5210 adapters
Four integrated 10 gigabit ethernet ports
12 Gbps SAS internal storage connectivity
Maximum of 24 drive bays
To create a fully integrated NeXtScale cluster, which configuration tool must be used?
LESC
X-config
PSAT
SSCT
Which two Books support System x3850 X6 and x3950 X6 hot swap functionality? (Select two.)
Primary I/O Book
Compute Book
Full-length IO Book
Half-length IO Book
Memory Book
A customer has an installed IBM BladeCenter H with HS23 blades that have two NVIDIA GPUs connected. The customer wants to move to the Flex System and x240 M5 blades with NVIDIA GPUs. What should the technical specialist tell this customer?
The flex system x240 m5 can support an NVIDIA GPU directly on the flex system x240 M5 planar board
Multiple NVIDIA GPUs can be suported on the flex system x240 M5 with multiple PCI expansion enclosures
The flex system x240 M5 with the PCI Expansion enclosure will support one NVIDIA GPU
The existing NVIDIA GPUs can be reused on the Flex System x240 M5 with the PCI Expansion enclosure
Which Lenovo ThinkServer offers a unique hybrid option, with nine 3.5-inch and six 2.5-inch front-access drive bays in the front and two 2.5-inch drive bays in the back?
TS440
RS140
RD650
RD450
A customer approached Lenovo with a list of three competitive servers and is looking for a comparable Lenovo solution. Which tool is useful in providing a comparable Lenovo solution?
Lenovo Solutions Book
Lenovo Pre-Sales Advisor
Lenovo Quick Pick
The x86 Server Reference (xREF)
What is the maximum number of snapshots that can be licensed for a Lenovo S3200?
256
2048
1024
512
A customer has purchased an IBM Storwize V3700 storage system and requires high availability and constant monitoring of system health. Which feature can be configured to meet this requirement?
Service Assistant Tool
Hardware Installation Planning
Call Home
Graphical User Interface
A customer is looking for a Fibre Channel switch for their SAN fabric, but needs to ensure that the switch has redundant power supplies standard in case of a power outage. Which Lenovo-supplied SAN switch has a redundant power supply as standard?
Brocade SAN Switch 6505
Brocade SAN Switch 6510
Brocade SAN Switch 6520
Brocade SAN Switch 300
A customer plans to scale from one to nine Flex Chassis, each containing two Flex SI4093 Interconnect Modules per enclosure. Which top-of-rack switch supports nine Flex Chassis via 40 Gb connections?
Rackswitch G8332
Rackswitch G8124E
Rackswitch G8264
Rackswitch G8316R
The customer is installing an operating system. During the process, the customer has some "How-To" questions. Which Lenovo low-cost fee-based service offering can assist this customer?
Enterprise Solution Services
Lenovo Expert Technical Sales (LETS)/Brand Technical Sales (BTS)
Warranty Upgrade with HDDR
Remote Technical Support (RTS)/Remote Technology Consulting Services (RTCS)
A customer has a Flex System with two EN4093R switches installed. Both 40 Gb ports are utilized and there are four Flex System x240 M5 blades. Each blade has one CN4058S with six ports active. The EN4093R base switch has 24 licensed ports. Assuming the customer is using Flexible Port Mapping, how many ports are still available per switch before an upgrade license needs to be applied to the EN4093R switches?
2
6
0
4
What is supported by the System x3100 M5?
Intel Xeon E3-1200 v3
Dual processor socket system
10 gb LOM
Up to 32 HDD
A customer is trying to determine which versions of VMware are supported with their S3200. What two references could be viewed to determine this information? (Select two.)
Lenovo Serverproven
IBM SSIC
ThinkServer Option Compatibility Matrix
Lenovo Press Product Guide
VMWare Compatibility Guide
A customer purchased a Lenovo S3200 dual controller storage solution, with two expansion enclosures with a mix of 10K SAS HDD, 7.2K NL-SAS and SSD (SAS) drives. In order to achieve increased performance (higher IOPS), which licensed feature can be purchased?
S3200 1024 Snapshots Upgrade
Turbo Performance
SSD Data Tiering Upgrade
Easy Tiering Upgrade
Which Lenovo tool can be used to configure ThinkServer?
X-config
LESC
SSCT
PSAT
What are two examples of a RAS feature in System x X6? (Select two.)
Lenovo XClarity Administrator
Advanced Page Retire
Expansion Processor Book
EXFlash DIMMS
Advanced Processor Recovery
A customer wants to install nine Flex Chassis and use a single point of administration for networking.
Flex System Interconnect Fabric with two G8264CS switches and eighteen SI4093 switches
Flex System Interconnect Fabric with two G8332 switches and eighteen CN4093 switches
Flex System Interconnect Fabric with two G8264 switches and eighteen EN4093 switches
Lenovo XClarity Administrator with two G8264CS switches and eighteen EN4093 switches
Which two come as the default with the IBM Flex System FC5022 24-port 16 Gb SAN Scalable Switch? (Select two.)
Fabric Watch
Two 16Gb SFPs
ISL Trunking
12 Omni Ports
Full Fabric
Which server can support up to thirty-two 2.5-inch hot swap SAS/SATA drive bays?
System x3500 M5
System x3100 M5
System x3550 M5
System x3650 M5
Which two features are present in the RackSwitch G8052? (Select two.)
Four Omniports
Six 10Gb Ethernet ports
Forty-eight 10/100/1000BASE-T RJ-45 ports
Two Fibre Channel ports
Hot-swappable power supplies
What benefit is offered by rack servers when compared with tower servers?
Rack servers consume less power
Rack servers are identified with a rack number (U) and Light Path Diagnostics
Rack servers mount into a rack cabinet, whick densely populates multiple server into a small space.
Rack servers support advanced management and PDU management.
If more storage capacity is required on the Flex System x240 M5, whicj option can be used?
Flex System Storage Expansion Node with Fibre Channel drives
Flex System PcIe expansion node with Teradici card installed
Flex System PcIe expansion node with GPU installed
Flex System Storage Expansion Node with SAS drives
Which system should be recommended if the customer says they need a minimum of 1.5 TB of memory and two Intel E7 processors in a blade form factor?
Flex System x440
Flex System x280 X6
System x3850 X6
System x3950 X6
A customer is looking for a blade chassis that runs on DC power and is NEBS Level 3 compliant. Which chassis should be used?
NextScale n1200 Enclosure
Lenovo Flex System Enterprise Chassis
Lenovo Flex System Carrier-Grade Chassis
Bladecenter H
Which of the following Flex switch options support only Fibre Channel?
Flex SI4091 and Flex SI4093
Flex CN4093 and Flex EN4023
Flex FC5022 and Flex FC3171
Flex EN4093 and Flex EN6131
A customer is looking for a server that can be cooled using water. Which server should be proposed?
NextScale nx360 M5 WCT
System x3850 X6
Flex System x240 M5
Thinkserver RD350
Which Lenovo ThinkServer is 2U in size, supports up to two processors, and has a maximum of 16 memory slots?
RD350
RD650
RS140
RD450
A customer is in a space-constrained datacenter and needs to add four x86 servers, two 10 Gb Ethernet switches, and two 16 Gb SAN switches. The current Ethernet core switch is Cisco and the SAN core switch is Brocade. The customer will double the number of servers over the next 90 days. Which solution meets this customer's requirements, uses the least amount of rack space and is the easiest to integrate into their existing infrastructure?
Four System x3550 Servers, two Rackswitch G8124E and two Brocade 300 switches
Four System x3650 Servers, two Rackswitch G8124E and two Brocade 300 switches
Flex System chassis with four Flex System x240 M5 blades, two CN4093 switches ì, and two FC3171 SAn Switches
Flex System chassis with four Flex System x240 M5 blades, two SI4093 switches, and two FC5022 SAn Switches
A customer requires a Lenovo S3200 with one expansion tray that is directly attached to three hosts, all connected redundantly with SAS. How many SAS cables does the configuration require?
10
6
8
12
Which 16 Gb Fibre Channel storage device can scale three storage expansion enclosures?
Lenovo E1012
Lenovo S3200
IBM Storwize v3700
Lenovo S2200
Which system contains a maximum of one processor?
X3650 M5
X3500 M5
X3250 M5
X3550 M5
A customer would like to try a function licensed by Feature on Demand (FoD). How long does the trial period last?
30 days
60 days
120 days
90 days
A customer purchased an IBM Storwize V3700 storage system and needs backup, clone and snapshot. Which option meets this requirement?
FlashCopy
Storage Migration
Easy Tier
Remote Copy
What is the storage capacity of the NeXtScale expansion tray?
Up to 36 TB
Up to 96Tb
Up to 42Tb
Up to 24 Tb
Which two statements are true about iSCSI? (Select two.)
ISCSI can operate over fiber optic cables
ISCSI is a Layer 4 routable protocol
ISCSI requires a dedicated IP network for storage traffic
ISCSI uses World Wide Names as unique identifiers
ISCSI is a Layer 3 routable protocol
A customer wants to upgrade their Lenovo S2200 to an S3200. What is the upgrade process?
The S2200 can be upgraded with a firmware update on the controllers
The S2200 can be upgraded by adding S3200 feature licenses in the Lenovo SAn Manager
The S2200 can be upgraded by changing the CNC personality ports in both controllers
The S2200 can be upgraded to the S3200 by replacing the RAID controllers in the controller enclosure
What is the factory default user name and password for a newly-installed Flex Enterprise Chassis?
The default CMM user name is USERID and the default password is Passw0rd (note the number zero, not the letter O)
The default CMM user name is USERID and the default password is PASSW0RD (note the number zero, not the letter O)
The default CMM user name is Userid and the default password is P@ssword
The default CMM user name is admin and the default password is admin
A customer requires both InfiniBand and Ethernet connectivity on a Flex System x240 M5 node. What is the maximum number of usable ports that are possible on each node?
Four ethernet and two infiniband
Six ethernet and two infiniband
One ethernet and two infiniband
Two ethernet and two infiniband
Which two features are present in the RackSwitch G8296? (Select two.)
1U form factor
Ten 40Gb QSFP ports
2U form factor
2 Infiniband ports
Ninety-six 40Gb QSFP ports
A customer is looking for:• a 1U server with two processors • 1.5 TB of RAM • redundant power supply • support for only one GPU • ability to use an IMM for systems management Which Lenovo x86 server will meet these requirements?
X3250 M5
ThinkServer RD350
ThinkServer Rd550
System x3550 M5
While walking through a data center, a business partner notices that a number of Lenovo System x servers have many fault or failure lights on them. In the past, the partner has never been remotely notified that something is failing until after it does fail. Which product or feature could help the customer identify and monitor problems?
KVM
XClarity
UPS
PFA
A small business requires a low-cost System x3650 M5 server, configured with a minimum number of I/O PCIe slots. What is the appropriate configuration for this customer?
A 2-processor x3650 M5 system with a minimum of two power supplies
A 2-processor x3650 M5 system with no PCIe riser cards
A 1-processor x3650 M5 system with no PCIe riser cards
A 1-processr x3650 M5 system with a minimum of one PCIe riser card
A customer wants to include a switch in the blade chassis that only supports Layer 2 functionality, while being able to provide 40 Gb connectivity to the core switch. Which Flex System switch should be proposed to this customer?
CN4093
EN4093R
SI4091
SI4093
What should a customer purchase if they want to be remotely guided through a server install?
A 24x7 warranty
KVM
RTS/RTCS
LBS
A customer with an installed IBM BladeCenter H wants to add three of the new e5-26xx v3 Intel processor blades to their existing BladeCenter H. Which migration route should be suggested for this customer?
Flex System with x240 M5 blades
Additional HS23 blades
Flex System with x880 blades
Flex System with x440 blades
Which Lenovo resources/tools contain information on Operating System support for System x servers?
Standalone Solutions Configuration Tool (SSCT)
Serverproven
Power Configurator
X-config
A System x3550 M5 server is configured with an M5210 RAID adapter, with a 1 GB flash cache option installed. The customer wants to leverage SSDs in order to accelerate the performance of their HDD volumes. Which feature would the customer license and enable on their RAID card in order to have this functionality?
Lenovo ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade
Lenovo ServeRAID M5200 Series SSD Caching Enabler
Lenovo ServeRAID M5200 Series Performance Accelerator
Lenovo ServeRAID M5200 Series RAID 6 Upgrade
A customer has a Cisco Nexus 5000 switch with all 10 Gb ports. What cable does Lenovo recommend for connectivity from the SI4093 to a Nexus 5000 that is three meters away?
Three meter active Lenovo DAC Cable
Three meter passive Lwnovo DAC CAble
SX SFP in Flex with Fiber Cable to SFP+ in Nexus 5000
10Gb SFP+ in Flex with Fiber Cable to SFP+ in Nexus 5000
What is the maximum amount of memory that can be addressed by the System x3950 X6?
12 TB
15 TB
9 TB
6 TB
Which cable can be used to connect a System x3650 M5 to an Ultra Density Enterprise C19-13 PDU+ Module?
Power Cable - C13 /NEMA 5-15P
DPI 32a Line Cord (IEC 309 3P+N+G)
European 10A line C13 to CEE 7/7
C13 to IEC 320-C14 Rack power cable
A customer: • has a 1 Gb network is experiencing a bottleneck due to a new database that was recently implemented on older server technology • has run out of rack space to install additional servers • is out of power to the data center • has very little cooling going into the data center The customer requested a consolidation study be done, and the results have suggested a collapse of 45 servers to 14 2-processor socket servers with an increase of bandwidth to 10 Gb. What is the correct solution?
One Flex System Enterprise Chassis with Flex System Fabric EN4093R switches and x240 M5 nodes
Fourteen Thinkserver RS140 servers with two 10Gb network connections and two RackSwitch G8264 network switches
One System x3950 X6 with eight processor books
Two Flex x880 X6 servers with four 10Gb Ethernet ports
Which statement is true regarding the Lenovo XClarity Administrator?
It is a Virtual appliance that does not require a dedicated Flex Node
It is an upward integration module that requires a dedicated Flex node
It is an hypervisor that does not require a dedicated Flex node
It is a software appliance that requires a dedicated Flex node
What is true when comparing the Flex System FC5022 16gb san scalable switch and the Flex system fc5022 24-port 16gb san scalable switch?
Only the flex system FC 24-port 16gb san scalable switch can expand to the full capability of 48 ports with FOD
Both models can add Fod licences, to end up with the same number of ports and management functionality
Both models can be upfraded to support same number of ports bu only the Flex System FC5022 24 port can have management ìfunctions
Only the flex system FC5022 24-port 16 GB SAN Scalable switch can have ISL trunking and/or Fabric Watch enabled with FOD
The customer is is interested in deploying a desktop virtualization solution that requires access to a shared storage system and that supports the maximum number of hard drives. Which storage solution should be proposed?
IBM Storwize V3700
Lenovo SA120
Lenovo S3200
Lenovo S2200
A customer wants to refresh six older servers with newer technology. They have an existing LAN and SAN infrastructure, with available ports on installed switches. Each server currently has four LAN and two SAN connections to the switches. The customer tells the sales specialist that space is at a premium in the data center. They expect to only need three new servers by utilizing virtualization. Which technology should be recommended to this customer?
2U rack optimized servers
1U rack optimized servers
Flex System
Nextscale
A customer has purchased a ThinkServer RD550. They want to use ThinkServer Deployment Manager to assist with configuring the server and deploying an operating system. How does the customer access ThinkServer Deployment Manager?
Download the TDM image and create a bootable CD
Press and hold the powert button on the front of the server to automatically boot into Thinkserver Deployment Manager
Launch Thinkserver Deployment Manager from the installation USB key
Press F10 during the boot process
What is the maximum number of Fibre Channel adapters and SAN ports that the Flex System x240 M5 can support without any expansion units?
One adapter with two 16gb ports
One adapter with two 8gb ports
Two adapters, each with two 8gb ports
One adapter with four 16gb ports
 
 
{"name":"Lenovo Technical Sales", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"1. Which two statements are true regarding Lenovo XClarity Integrator? (Select two.), A customer wants to install a Windows operating system on a System x server. Which tool helps with this installation process?, A customer is looking at different x86 solutions, including a UCS B-series solution. What Lenovo product should the technical specialist propose in order to offer a similar form factor?","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}
Powered by: Quiz Maker