The effectivity of the Philippine Electronics Code (consisting of 4 books) is On _______
February 20, 2017
February 10, 2016
February 20, 2016
February 20, 2016
The Philippine Electronics Code Book 1 is:
Telecommunications Facilities DistributionSystem
Fire Detection and Alarm System
Cable Television System
Distributed Antenna System
The Philippine Electronics Code Book 2 is
Telecommunications Facitifies DistributionSystem
Cable Television System
Distributed Antenna System
Fire Detection and Alarm System
The Philippine Electronics Code Book 3 is:
Cable Television System
Telecommunications Facilities Distribution System
Fire Detection and Alarm System
Distributed Antenna System
The Philippine Electronics Code Book 4 is
Distributed Antenna System
Fire Detection and Alarm System
Telecommunications Facilities Distribution System
Cable Television System
The PEC Book 1 (Telecommunications Facilities Distribution System) consists of how many chapters?
8
12
10
5
The PEC Book 2 (Fire Detection and Alarm System or FDAS) is composed of how many chapters?
2
4
3
12
The PEC Book 3 Which is for Cable Television System is composed Of how many chapters?
10
12
8
5
The PEC Book 4 (Distribution Antenna System)
6
2
4
1
What is otherwise known as Revised Fire Code of the Philippines of 2008?
R. A No. 8293
R. A No. 9514
R. A No. 11058
R. A No. 1940
The BECE Resolution No. 12, series of2014 which is the Adoption of the Code of Technical Standards of Practice or the Philippine Electronics Code was done in the City of Manila on:
December 19, 2012
January 29, 2014
December 29, 2014
January 19, 2012
The adoption of the code of technical standards of practice, also known as the Philippine Electronics Code, consisting of books I, 2,3 and 4 as part of the rules and regulations governing the practice of Electronics Engineering and as a referral code to the National Building Code of the Philippines is Board of Electronics Engineering Series of 2014 Resolution NO.
11
15
12
6
What is otherwise known as Anti-Cable TV and Cable Internet Tapping Act of 2013?
R.A No. 10515
R.A No. 11058
R.A No. 5734
R.A No. 8293
What states that "The Board shall adopt a Code of Ethics and the Code of Technical Standards of Practice for Electronics Engineers and Electronics Technicians which shall be promulgated by the Accredited Professional Organization?
Article IV, Section 34
Article II, Section 16
Article I, Section 5
Article IV, Section 30
The implementation of R. A. NO. 9292 known as the "Electronics Law of 2004" in the process and approval of building permits for building and structures required under Presidential Decree NO. 1096, the National Building Code Of the Philippines is covered in the Board of Electronics Engineering Memorandum Circular
2007-23
2009-23
2007-19
2012-23
National Building Code of the Philippines is
P.D. 1096
P.D. 148
P.D. 1210
P.D. 198
What DILG Memorandum directs I-GUS to engage the assignment of duly registered PECE or ECE as part Of the Of staff Of provincial or municipal/city government? Memorandum Circular NO.
2013 – 01
2009 – 01
2012 – 01
None of the choices
What DILG memorandum circular informing the local government about the implementation of the Electronics Engineering Law of2004?
MC No. 2013-01
MC No. 2009-01
MC No. 2012-01
None of the choices
For outside plant system, Who Shall be appointed to take charge of Outside Plant installation and maintenance to ensure the quality and safety of the work?
None of the choices
Both are correct
Professional Electronics Engineer or Licensed / Registered Electronics Engineer
A registered Professional Electronics Engineer (PECE) and has experience in the proper design, application, installation, and testing as FDAS as cettified by IECEP
In Philippine Electronics Code, the term "SHOULD or SHOULD NOT"
" are permissive Rules"
Mandatory Rules
Optional Rule
None of the choices
In Philippine Electronics Code, the term "SHALL or SHALL NOT*
Mandatory Rules
Are permissive Rules
Optional Rule
None of the choices
In Philippine Electronics Code, the term "MAY" is a/an
Mandatory Rules
Permissive Rules
Optional Rule
None of the choices
Under the PEC Book 3 — Cable Television System, to secure an Electronic Permit. A sets Of complete minimum Of electronic plans and specifications signed and sealed by professional Electronics Engineers must be submitted.
7
2
5
13
What are th e standard sizes for electronics plans and drawings?
A0 size (841 mm x 1189 mm) A1 size (594 mm x mm) A2 size (420 mm x 594 mm) A3 size (297 mm x 420 mm)
A0 size (740 mm x 1089 mm) A1 size (594 mm x mm) A2 size (420 mm x 594 mm) A3 size (297 mm x 420 mm)
A0 size (841 mm x 1189 mm) A1 size (594 mm x mm) A2 size (420 mm x 594 mm) A3 size (320 mm x 400 mm)
None of the choices
What oversees the creation, circulation and use of standards and guidelines that directly impact businesses in various sectors?
PCAB
ANSI
IECEP
IEEE
What IEEE standard is for Ethernet?
852.3
752.5
802.3
651.3
What IEEE standard is for Power over Ethernet
802.3an
802.3
802.3af
802.3az
What is the maximum allowable horizontal cabling length in a permanent link?
100 m or 328 ft
90 m or 295 ft
85 m or 278.9 ft
110 m or 361 ft
What is the total allowable channel link length?
90 m or 295 ft
100m or 328ft
85 m or 278.9 ft
110 m or 361 ft
The total length of the patch cords used in the work area shall not exceed
Exceed 8 m or 26 ft
Exceed 5 m or 16 ft
Exceed 2 m or 6.5 ft
Exceed 10 m or 33 ft
For grounding, if water pipes are used, they must be bonded to another electrode type within__ of entrance to ensure a reliable ground.
4.7 m or 15.5
5.5 m or 18
5ft or 1.5m
3.5 m or 11.5 ft
What is the minimum vertical clearance for installation of cable above residential driveways?
5.5 m or 18
4.7 m or 15.5
3.5 m or 11.5 ft
5ft or 1.5m
What is the minimum vertical clearance for installation of cable above sidewalk and other
5.5 m or 18
5ft or 1.5m
3.5 m or 11.5 ft
4.7 m or 15.5
What is the minimum vertical clearance for installation of cable over the roofs not accessible to pedestrians? RDE
3.5 m or 11.5 ft
5ft or 1.5m
7.3 m or 24 ft
4.7 m or 15.5
What is the minimum horizontal and vertical clearance for installation of cable above signs, chimneys, billboards, radio and television antennas and other installations not classified
1 m or 3 ft
7.3 m or 24 ft
3.5 m or 11.5 ft
4.7 m or 15.5
What is the minimum vertical clearance for installation of cable over the balconies and roofs accessible to pedestrians?
1m or 3ft
3.2 m or 10.5 ft
3.5 m or 11.5 ft
4.7 m or 15.5 ft
What is the minimum horizontal and vertical clearance for installation of cable over light Or power service drops?
10m or 32ft
30 cm or 12 in
1.4 m or 4.5ft
3.5 m or 11.5 ft
What is the minimum horizontal and vertical clearance for installation of cable over lightning conductors? Pb1017elecc
10m or 32ft
30 cm or 12 in
10m or 32ft
1.4 m or 4.5ft
What is the minimum horizontal clearance for installation of cable to walls, projections, windows, balconies and areas accessible to pedestrians?
1 m or 3 ft
30 cm or 12 in
10m or 32ft
1.4 m or 4.5ft
What is defined as the physical /electrical interconnection between telecommunications closets and equipment rooms?
Bonding
Backbone wiring
Ground loop
Straight Tip (ST)
What is defined as the permanent joining of metallic parts to form an electrically conductive path that will ensure electrical continuity and the capacity to safely conduct any current likely to be imposed?
Backbone wiring
Bonding
Ground loop
Straight Tip (ST)
What is defined as unwanted ground current flowing back and forth between two devices that are grounded at two Or more points?
Ground loop
Backbone wiring
Bonding
Straight Tip (ST)
What is defined as an electromagnetic that occurs in a cable run alongside Other signal-carrying cables?
Transition point
Zone enclosure
Alien Crosstalk
Wire map test
What is described as a location in the horizontal cabling where flat under carpet cable connects to round cable?
Alien Crosstalk
Zone enclosure
Wire map test
Transition point
Telecommunications enclosure (TE) is a Case or housing for telecommunication equipment, cable termination and cross-connect cables. It is also referred to as ____
Alien Crosstalk
Transition point
Wire map test
Zone enclosure
What is the most common way to establish the telecommunications ground?
Use the electrical service ground
Cut the wire power
Test the supply volt if its stable
All of the above
What test looks for cable faults (opens, shorts, grounds) and measures the electrical conductivity and continuity of the cable system
Wire map test
Optical Network Terminal (ONT)
Optical Line Terminal (OLT)
None of the choices
What is a device that transforms incoming optical signals into electrical signals and vice versa at a customer's premises?
Optical Line Terminal (OLT)
Optical Network Terminal (ONT)
Use the electrical service ground
Wire map test
What device serves as the service provider endpoint of a passive optical network?
Optical Network Terminal (ONT)
Optical Line Terminal (OLT)
Wire map test
Use the electrical service ground
What is the reason why you should not paint premise cables?
A. Paint can alter the flame and smoke characteristics.
B. Paint obscures the flame resistance rating of the cable.
C. Painting the cable will void the product warranty.
D. All choices are correct
What refers to a deep-fiber network design in which the coax portion of the hybrid fiber(HFC) network is replaced by a single fiber passive optical network?
Premises Connection Device (PCD)
Set Top Terminal (STT)
Straight Tip (ST)
Radio frequency over glass (RFoG)
What refers to an access point that serves as a demarcation and test point on the outside of a customer’s premises? It is a non-metallic wall mounted fiber box that offers splicing, patching and storage for drop cables.
Radio frequency over glass (RFoG)
Premises Connection Device (PCD)
Set Top Terminal (STT)
Straight Tip (ST)
For service entrance cable, a minimum___ of coaxial cable. Solid aluminum__ohms shall be laid out from outside plant to service entrance box of the building vial aerial or underground.
0.500, 75 ohms
0.700, 300 ohms
0.250, 50 ohms
None of the choices
For cable TV system, antenna towers and satellite dish shall be equipped with lightning protection. Lightning rods shall __be long___ in diameter.
2.4m, 16 mm
3.4m, 12 mm
5.4m, 20 mm
4.4m, 10 mm
In headend or core system of cable TV, grounding resistance Of the antenna measured at any point in the grounding system shall not be greater than
10 ohms
5 ohms
8 ohms
12 ohms
In the head end or core system of cable TV what should be used to connect the lightning conductivity and continuity of the cable system? Rod and ground rod with appropriate bonding
AWG # 12
AWG # 10
AWG # 6
AWG # 5
What is strongly recommended to use To secure cable bundles?
Cable wraps
VELCRO fasteners
Circular wire formation
None of the choices
What is the minimum clearance ofaerial service entrance from ground level when crossing the street?
3.5 m or 11.5 ft
5.5 m or 18 ft
1 m or 3.5 ft
1 m or 3 ft
What is the minimum clearance of aerial service entrance over area accessible to pedestrian only?
5.5 m or 18 ft
3.5 m or 11.5 ft
1 m or 3.5 ft
1 m or 3 ft
The minimum clearance between telephone entrance cable and power cable must be radial distance.
1 m or 3.5 ft
5.5 m or 18 ft
1 m or 3 ft
3.5 m or 11.5 ft
In order for shielded cable to be reducing the effects of EMI and RFI, It must be
Backbone wiring
Straight Tip (ST)
Properly bonded to ground at the horizontal cross connect
Ground loop
What type of connector provides loss but is not considered a pull or proof connector?
Bonding
Straight Tip (ST)
Ground loop
Be properly bonded to ground at the horizontal cross connect
What type of connector provides moderate loss and is considered a pull or wiggle-proof connector?
Main cross-connect (NC)
Subscriber Connector (sc)
Straight Tip (ST)
None of the choices
What type of cross-connect that is in the ER for connecting entrance cables; backbone Cables
Subscriber Connector (sc)
Straight Tip (ST)
Main cross-connect (NC)
None of the choices
Antennas used in a distributed antenna system Come in two-class types, namely
Omnidirectional and directional/panel antenna
Aerial entrance and underground entrance
Entrance facilities (EF)
None of the choices
What are the two types of service entrance for telecommunication pathways and Spaces?
Omnidirectional and directional/panel antenna
Aerial entrance and underground entrance
Entrance facilities (EF)
Individual DAS and common or shared DAS
In telecommunications spaces, what typically serves as the point of demarcation for the service provider (SP)?
Exit facilities (EF)
Entrance facilities (EF)
Main facilities (MF)
Canteen facilities (CF)
What are the two classes of Distributed Antenna System (DAS)?
Common or shared DAS
Individual DAS and common or shared DAS
Multiple DAS and Indvidual DAS
Uncommon and Common DAS
In what type of distributed antenna system (DAS) where every antenna is simultaneously propagating different wireless services provided by wireless service providers who have agreed to share the common DAS?
Multiple DAS and Indvidual DAS
Individual DAS and common or shared DAS
Common or shared DAS
Uncommon and Common DAS
What is the frequency (in MHz) ofthe omni-directional antenna used in
806 - 960 and 1210 — 2400
806 - 960 and 1710 — 3300
806 - 960 and 1710 — 2700
806 - 960 and 1510 — 2700
What is the impedance (in ohms) of the omni-directional antenna used in distribution antenna system?
40
50
30
20
What is the operating temperature of the omni-directional antenna used in distribution antenna system?
-40oC to +60oC
-20oC to +50oC
-10oC to +30oC
-10oC to +20oC
What is the frequency range (in MHz) of panel antenna for microcell?
A. 806-960
B. 1710-2300
C. 2400-2700
D. All choices are correct
What is feeders to splitters, couplers and combinersand in the connection port of the BTS itself?
Jumper cable
Radiating cable
Leaky cable
None of the choices
What type of cable is highly recommended for use in small areas where there is a strong need for dedicated coverage?
Jumper cable
UTP cable
Coax Cable
Radiating cable or leaky cable
Directional or panel antenna is a type of antenna that emits radio wave in one or ONO direction and usually has a beam width of degrees.
50 -55
60 -65
40 -45
30 -35
What type Of antenna is generally used to provide coverage in an open parking, lifts and elevators?
Directional antenna for microcell
Reference signal received power (RSRP)
Both A and B
None of the choices
What is the maximum power for panel antenna for microcell?
100 W
200 W
80 W
130 W
A circuit used to measure the strength Of an incoming signal.
Reference signal received power (RSRP)
Received signal strength indicator (RSSI)
Signal to interference plus noise ratio (SINR)
None of the choices
What is defined as the linear average over the power contribution in watts Of the resource elements that carry cell-specific reference signals within the considered measurement frequency bandwidth?
Reference signal received power (RSRP)
Received signal strength indicator (RSSI)
Signal to interference plus noise ratio (SINR)
None of the choices
What is defined as the power of a certain signal of interest divided by the sum of the interference power (from the other interfering signals) and the power of some background noise?
Signal to interference plus noise ratio (SINR)
Received signal strength indicator (RSSI)
Reference signal received power (RSRP)
None of the choices
The probability of a call in a circuit group being blocked or delayed for more than a specified interval, expressed as a vulgar fraction or decimal fraction.
Grade of Service
Quality Check
Circuit Analysis
Data Rate Sequence
What Is the normal range Of grade Of
2 % to 7 %
1 % to 5 %
5 % to 10 %
11 % to 15 %
For capacity design consideration, the grade of service shall be ____ or better.
1 %
4 %
3 %
2 %
A coverage area in which it does not pass the minimum KPI but enough to initiate and sustain a call, which can be used during emergencies.
Coverage area
Network area
Incidental coverage area
Subscriber area
Smoke detectors shall not be installed in which of the following ambient conditions?
A. Temperature is below 5'C
B. Temperature is above 45' C
C. Relative humidity is above 83 percent
D. All choices are correct
According to the Philippine Electronics Code.low rise buildings have number of floors between ___
1-5
6-15
36-70
16-35
An unwanted signal created by the mixing of two or more RF signals, caused by nonlinearity of the passive components in the RF path such as antennas, cable or connectors.
Hybrid active - passive DAS solution
Passive DAS solution
Passive intermodulation (PIM)
None of the above
Type of DAS design solution in which every antenna has a dedicated Remote
Radio Unit. Pure active DAS solution
Passive intermodulation (PIM)
Hybrid active - passive DAS solution
None of the choices
Type of DAS design solution in which it uses purely passive components and no line amplifier used on the system component.
Radio Unit. Pure active DAS solution
Passive DAS solution
Passive intermodulation (PIM)
Hybrid active - passive DAS solution
Type of DAS design solution in which every antenna has a dedicated Remote Radio Unit.
Pure active DAS solution
Passive DAS solution
Passive intermodulation (PIM)
Radio Unit. Pure active DAS solution
The remote radio unit (RRU) are linked to the baseband unit (BBU) via
Coax cable
Rg 258
Fiber optics cable
None of the choices
What conduit is used to provide protection oil the fiber optics cable?
A. Polwinyt chloride (PVC) pipe
B. Rigid steel conduit (RSC)
C. Intermediate metal conduit (IMC)
D. Choices are correct
What is the most commonly used protection for fiber optic cable?
Rigid steel conduit (RSC)
Intermediate metal conduit (IMC)
Polyvinyl chloride (PVC) pipe
None of the choices
What is the most efficient protection for fiber optic cable?
Electro metallic conduit (EMC)
Electro metallic tubing (ENT)
None of the choices
Electro metallic conduit (EMC) and electro metallic tubing (ENT)
Conduits are used for protection for all Of the following except
A. fiber Optic cable
B. ether-net cable
C. Coaxial cable
D. IF transport cable
A Component of an electricity supply system. Which divides an electrical power feed into subsidiary circuits, while providing a protective fuse or circuit breaker for each circuit, in a common enclosure
Alternating current panel distribution board
Busbar
Grounding pit
Annunciator
What conducts electricity within a switchboard, distribution board, substation, battery bank or Other electrical apparatus?
Alternating current panel distribution board
Busbar
Grounding pit
Annunciator
What is a final grounding in which the end of the Wire is grounded or connected to Earth for lightning and surge protection?
Alternating current panel distribution board
Busbar
Grounding pit
Annunciator
The acceptable ground resistance value is Or below.
2.5 Ohm
0.5 Ohm
3.5 Ohm
5.5 Ohm
{"name":"GEAS COACHING VOLUME 2 PART 1", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Test your knowledge on the Philippine Electronics Code with this comprehensive quiz. Whether you're a student, teacher, or a professional in the field, this quiz is designed to enhance your understanding of important regulations and standards in electronics engineering.Challenge yourself with questions covering:The Philippine Electronics Code's various booksIEEE standardsNational Building CodeFire Detection systems","img":"https:/images/course7.png"}