PTDEE - Inginerie Electrica [Lucian Toma]

An educational and engaging image depicting electrical engineering concepts such as circuit diagrams, transformers, and power lines, with a modern and sleek design.

PTDEE - Inginerie Electrica Quiz

Test your knowledge of electrical engineering concepts with our comprehensive quiz designed specifically for students and professionals in the field. Dive into questions that cover essential topics from voltage drops to network configurations and much more.

Featuring:

  • 30 challenging questions
  • Multiple choice format
  • Instant feedback on your answers
66 Questions16 MinutesCreated by ElectrifyingBrain54
Expresia componente transversale a caderii de tensiune faza-faza in functie de puterile trifazate: Activa(P), Reactiva (Q), Rezistenta (R) si Reactanta (X) ale liniei electrice si tensiunea nominala (Un) este:
ΔUab=(RQ-XP)/Un
ΔUab=(XP-RQ)/Un
ΔUab=(RP+XQ)/Un
In alegerea sectiunii conductoarelor liniilor electrica, regula lui Kelvin se refera la
Temperatura admisibila in regim permanent de lunga durata
Obtinerea unei sectiuni constante pentru toate tronsoanele liniei
Echilibrul dintre investitia suplimentara si beneficiul obtinut pe durata exploatarii
In cazul unei retele alimentate de la doua capete, curentul de circulatie depinde de
Impedantele tronsoanelor retelei
Marimea curentilor ceruti de consumatori
Defazaul dintre tensiunile de la cele doua capete
In regim normal de functionare curentul de sarcina al unei linii electrice
Poate lua orice valoare
Trebuie sa fie intotdeauna mai mic sau cel mult egal cu curentul admisibil
Poate depasi curentul admisibil pe perioade scurte de timp cu conditia Θcond <= Θadm
Neutrul retelelor electrice de joasa tensiune
Se leaga direct la pamant
Se trateaza prin bobina de stingere sau rezistor
Functioneaza izolat
Prin utilizarea expresiei ΔPL=RL(P^2+Q^2)/Un^2 in care RL este rezistenta liniei in [ Ω ],P si Q sunt puterea activa in [MW],respectiv puterea reactiva [Mvar] ,transportate pe linie iar Un este tensiune nominala de linie ,in [Kv],pierderile de putere activa pe o linie electrica se obtin in :
MW
W
KW
Caderea de tensiune algebrica pe o linie electrica se calculeaza cu DUab=ΔUab daca:
Curentul prin linie are un caracter capacitiv
Se neglijeaza rezistenta liniei electrice
Se neglijeaza componenta transversala a caderii de tensiune
Nodul de separare a curentilor (puterilor) dintr-o retea electrica simplu buclata are proprietatea
Este nodul alimentat de la ambele surse
Este nodul in care pierderile de putere sunt cele mai reduse
Este nodul cu cel mai ridicat nivel de tensiune din retea
Expresia componentei longitudinale a caderii de tensiune faza-faza in functie de puterile trifazate activa P si reactiva Q ,rezistenta R si reactanta X ale liniei electrice si tensiunea nominala Un este :
ΔUab=(RQ+XP)/Un
ΔUab=(XP-RQ)/Un
ΔUab=(RP+XQ)/Un
Prin utilizarea expresiei ΔPL=RL(P^2+Q^2)/Un^2 in care RL este rezistenta liniei in [ Ω ],P si Q sunt puterea activa in [kW],respectiv puterea reactiva [kvar] ,transportate pe linie iar Un este tensiune nominala de linie ,in [Kv],pierderile de putere activa pe o linie electrica se obtin in :
W
KW
Mw
Conexiunea infasurarilor transformatoarelor pe parte de inalta tensiune
Se asigura prin dispozitive speciale
Este de tip stea
Este de tip triunghi
Calculul regimului permanent folosind medota "ascendent-descendent" se realizeaza pentru
Verificarea dimensionarii tronsoanelor de medie tensiune
Calculul tensiunilor la noduri
Compensare puterii reactive
Neutrul retelelor electrice de inalta tensiune:
Funtioneaza izolat
Se trateaza prin bobine de stingere
Se leaga direct la pamant
In RE cu neutrul izolat, prin punerea la pamant a unei faze, potentialul punctului neutru
Devina egal cu U linie
Devine egal cu U faza
Nu se modifica
Tratarea neutrului in RE prin rezistor are avantajul ca:
Consumatorii pot fi in continuare alimentati in caz de defect
Se asigura o selectivitate mai buna a liniei cu defect
Se asigura valori simetrice ale U pe cele 3 faze
RE de JT au un pronuntat caracter
Rezistiv
Reactiv
Atat reactiv cat si rezistiv
In RE cu neutrul izolat, in cazul aparitiei unui defect monofazat:
Tensiunile fata de pamant ale fazelor sanatoase cresc sqrt3
Tensiunile fata de neutru ale fazele sanatoase cresc de sqrt3
Apare o componenta a tensiunii de secventa zero
Curentul de defect are un caracter
Capacitiv
Rezistiv
Inductiv
Neutrul RE de MT
Se leaga direct la pamant
Funtioneaza izolat
Se trateaza prin rezistor sau bobina de stingere
Sectiunea conductoarelor determinata pe vaza criteriului caderii admisibile de tensiune, in ipoteza j constant, este:
Mai mare pentru tronsoanele mai apropiate de nodul surse
Mai mica pentru tonsoanele mai apropiate de nodul sursa
Aceeasi pentru toate tronsoanele
In cazul aruncarii sarcinilor la capetele retelei:
Curentul de circulatie rezultant este egal cu zero
Pierderile de putere pe reteaua echivalenta se conserva
Nu rezulta caderi de tensiune
In etapa descendent din metoda "ascendent-descendent" se calculeaza:
Atat tensiunile la noduri cat si circulatia de puteri prin laturi
Circulatia de puteri prin laturi
Tensiunile la noduri
Reducerea pierderilor de putere intr-o retea se realizeaza prin
Compensarea curentului de circulatie
Limitarea circulatiei de putere reativa
Functionarea radiala
Conexiuna infasurarilor trafo pe parte de MT
Este de tip triunghi
Este de tip stea
Se asigura prin dispozitive speciale
Bobinele de tingere conectate intre neutrul RE si pamant au rolul
Sa aplatizeze forma undei de U in cazul unui sc.
De a compensa curentul capacitiv de punere la pamant
De a compensa Q capacitiva produsa de linie atfel incat sa se mentina un nivel corespunzator
Printr-o linie electrica cu mai multi consumatori alimentata de la doua capete, functionant in gol, exista un curent de circulatie
Doar daca tensiunile la cele doua capete sunt diferite
Indiferent de valorile tensiunilor la cele doua capete
Doar ca U la cele doua capete sunt egale
Intr-o RE alimentata de la nodurile A si B curentul de egalizare apare daca
Tensiunile la cepete sunt in faza
Tensiunile la capete sunt diferite
Tensiunile la capete sunt egale
In regim simetric si echilibrat, potentialul punctului neutru este:
Egal cu zero
Putin diferit de zero
Depinde de valoarea cumulata
In RE cu neutrul tratat prin rezistor, la aparitia unui defect cu pamantul:
Arcul electrice se autostinge prin prima trecere prin zero a curentului
Protectiile prin relee vad o componenta de secventa zero si deconecteaza imediat linia cu defect
Consumatorii pot fi alimentati pe o perioada de maxim 2 ore
In RE cu neutrul izolat, curentul de defect
Are o valoare mai mare pentru LEC
Depinde numai de nivelul de U
Are o valoare mai mare pentru LEA
In etapa ascendent din metoda "ascendent - descendent" se calculeaza
Tensiunile
Circulatia de puteri pe laturi
Atat tensiunile cat si ciculatia de puteri pe laturi
Componenta transversala a caderii de tensiune pentru linia electrica cu un singur consumator se poate neglija atunci cand
Factorul de putere la consumator are valoarea apropiata de unitate
Tensiuna nodului de alimentare are valoarea apropiata de cea nominala
Unghiu de defazaj dintre tensiune la cele doua capete ale liniei are valor neglijabile
Curentii injectati la cele doua noduri ale unei linii electrice simplu buclate funcionand cu tensiuni egale la capete depinde de:
Curentul de egalizare
Curentii de la consumatori
Curentul de mers in gol
Prin asigurarea uneo conditii de securitate, bobine de stingere este
Supradimensionata
Subdimensionata
Dimensionata la rezonanta
Intr-o retea electrica cu sarcini dezechilibrate
Curentii sunt defazati inaintea tensiunilor
Potentialul punctului neutru device egal cu potentialul de faza
Tensiunile sunt asimetrice
Pnetru o linie electrica avand impedanta Z=R+jX prin care circula curentlui inductiv I=Ia-jLr expresia caderii de tensiune fazoriala este:
DV= XIa-jRlr
DV=RIa-jXlr
DV= RIa+jXlr+j(XIa-jRIr)
Pierderile de putere activa in transformator depind de:
Pierderile de putere activa la mersul in gol
Tensiunea de scurcircuit
Curentul de mers in gol
Verificarea caderilor de tensiune intr-o retea electrica se face prin compararea caderii admisibile de tensiune cu valoarea maxima a:
Caderii de tensiune algebrica
Componentei transversale a caderii de tensiune
Caderii de tensiune fazoriala
In cazul retelelor electrice cu neutrul legat direct la pamant, aparitia unui defect monofazat atrage urmatoarele consecinte:
Valori constante ale tensiunilor, dar cu aparitia unor supracurenti
Valori ale tensiunilor de fazele sanatoase mai mari de V3 ori
Curenti mici, dar supratensiuni semnificative
Demensionarea conductoarelor unei linii electrice radiale cu mai multi consumatori, in ipoteza densitatii de curent constante, conduce:
La acelasi curent prin tronsoane
La aceeasi valoare a sectiunii pentru toate tronsoanele
La valori diferite ale sectiunii tronsoanelor
Metoda " ascendent-descendent" se utilizeaza pentru calculul electric al:
Retelelor radiale
Retelelor complex buclate
Retelelor simplu buclate
In retelele electrice cu neutrul legat direct la pamant raportul X0/X+ trebuie sa fie
1<X0/X+<3
X0/X+<3
1<X0/X+
Conexinuea infasurarilor transformatoarelor pe partea de joasa tensiune:
Este de tip stea
Se creeaza prin dispozitive speciale
Este de tip triunghi
Caderea de tensiune fazoriala pe o linie electrica cu un singur consumator prezintaL
Raportul dintre puterea complexa la consumator si curentul complex prin linie
Produsul dintre impedanta longitudinala si curentul complex prin linie
Diferenta dintre modulele tensiunilor la cele doua capete
Caderea de tensiune algebrica din diagrama fazoriala pentru o linie electrica reprezinta:
Diferenta dintre tensiunile efective la cele doua capete
Modulul caderii de tensiune fazoriale
Modulul diferentei dintre tensiunile la cele doua capete
Pierderile de mers in gol ale unui transformator functionand in gol sunt fata de pierderile in infasurari:
Mai mici
Mai mari
Aproximativ egale
La metoda "ascendent-descendent" pentru calculul regimului permanent al unei retele electrice, testul de convergenta consta in verificarea
Modulului diferentelor tensiunilor intre doua iteratii succesive
Diferenta modulelor tensiunilor intre doua iteratii succesive.
Modulului diferentelor puterilor intre doua iteratii succesive
In retelele electrice cu neutrul legat direct la pamant, prin punerea la pamant a unei faze potentialul punctului neutru:
Devine egal cu tensiune de linie
Nu se modifica
Devine egal cu tensiunea de faza
In exploatarea liniilor electrice in cablu se admite depasirea curentului admisibil cu conditia:
Sa nu se depaseasca temperatura admisibila impusa de clasa de izolatie
Sa nu se depaseasca valoarea admisa a caderii de tensiune
Nu se admit depasiri ale curentului admisibil
Densitatea economica de curent:
Inversa proportional cu rezistivitatea
Nu depinde de rezistivitate
Direct proportional cu rezistivitatea
Din punct de vedere al asigurarii continuitatii in alimentare a consumatorilor, cea mai buna solutie de tratare a neutrului este:
Legarea directa la pamant
Bobina de stingere
Rezistorul
Pierderile de putere activa in liniile electrice, datorate efectului Joule, fac parte din categoria:
Pierderilor comerciale
Consumului propriu tehnologic
Pierderilor tehnice
Dimensionarea conductoarelor unei linii electrice radiale cu mai multi consumatori, ipoteza s=ct, conduce la:
Aceeasi valoare a sectiunii pentru toate tronsoanele
Valori diferite ale sectiunii tronsoanelor
Acelasi curent prin tronsoane
Configuratiile complexe buclate se utilizeaza pentru retelele electrice de distributie din:
Zonele rurale
Aglomeratiile urbane
Zonele cu densitatea mica de sarcina
Scaderea factorului de putere al consumatorilor alimentati printr-o linie radiala conduce la:
Tensiuni mai mari la consumatori
Pierderi de putere mai mari pe linie
Putere reactiva produse pe linie mai mare
Retelele electrice de distributie cu configuratie buclata se exploateaza sectionat (debuclat) pentru:
Limitarea extinderii zonei afectate de scurtcircuit
Reducerea pierderilor de putere si energie
Reducerea caderilor de tensiune
Comutatorul de ploturi al transformatoarelor este amplasat pe partea
Infasurarea de tensiune mai joasa
Infasurarea de tensiune mai inalta
Infasurarea de tensiune nominala fixa
Cresterea nivelului de tensiune intr-un nod al unei retele electrice se obtine folosind:
Bobine de compensare
Rezistoare in derivatie
Baterii cu condensatoare
Se considera un consumator alimentat prin intermediul unui transformator cu reglaj sub sarcina avand schema echivalenta prezenta in figura alaturate. Stiind ca transformatorul dispune de posibilitatea reglarii tensiunii, pentru a obtine tensiune dorita la consumator in cazul unei scaderi a sarcini, este necesar:
Cresterea valorii raportului de transformare
Reducerea valorii raportului de transformare
Mentinerea aceleiasi valori raportului de transformare
Intr-o retea electrica exista o dependenta stransa intre:
P si U respectiv Q si Theta.
P si F respectiv Q si U.
P si U respectiv Q si f.
Tratarea prin rezistor a neutrului se aplica in retelele de:
Joasa tensiune
Medie tensiune
Inalta tensiune
Retelele electrice de inalta tensiune au neutrul:
Izolat
Tratat prin rezistor
Legat direct la pamant
Un defect monofazat este vazut ca un scurcircuit daca neutrul retelei electrice este:
Tratat prin Rezistor
Tratat prin Bobina
Izolat
Urmatoarea relatie exista intre puterea aparenta, tensiune si curent:
S=V3*U*I
S=V3*V*I
S=V3UI*
Reducerea pierderilor de putere intr-o retea se realizeaza prin:
Limitarea circulatiei de putere reactiva
Functionarea radiala
Compensarea curentului de scurcircuit
Reglajul primar de tensiune consta in:
Producerea locala de putere reactiva cu ajutorul unui compensator static/sincron
Actiunea RAT a generatoarelor la aparitia unei perturbatii
Optimizarea nivelului de tensiune la nivelul sistemului
{"name":"PTDEE - Inginerie Electrica [Lucian Toma]", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Test your knowledge of electrical engineering concepts with our comprehensive quiz designed specifically for students and professionals in the field. Dive into questions that cover essential topics from voltage drops to network configurations and much more.Featuring:30 challenging questionsMultiple choice formatInstant feedback on your answers","img":"https:/images/course3.png"}
Powered by: Quiz Maker