Foundations – not < _______ mm below the grade, may encroach ______mm into public sidewalk areas.
600, 500
600, 400
500, 300
600, 600
If only 2 exits required, shall be placed distance apart not < ____ of the perimeter area.
1/3
1/4
1/5
Inner courts shall be connected to a street or yard, or by a passageway – at least how many meters.
1.0
1.1
1.2
1.3
New construction w/c increases the height or area of an existing bldg./structures.
Addition
Renovation
Extension
Demolition
Spacing of rows of seats from back to back – not < ______mm (standard seating)
840
850
860
Non-structural facing brick, concrete, tile, metal, etc. Attached at the backing or structural components for the purpose of ornamentation.
Brick
Face
Stone
Veneer
If arcaded bldg, no chaflan reqtd notwithstanding the width of public street, <________m?
12
13
14
15
Width and Height of doors will be not < _____mm in width, not < ______m in height, opening will be 90 degrees and exit way clear width not < 700mm?
900, 2.1
800,2.0
900, 2.0
Distance of Exits – w/o sprinkler – ____m from exterior exit door, w/ sprinkler will be ____m?
45, 50
30, 60
45, 60
Sum of areas of openings must not exceed _____ % of sum of areas of walls?
50
20
40
60
Eaves over required windows not < _____. Minimum over from the side & rear property lines?
300 MM
600 MM
1000 MM
750 MM
Reviewing Stands, Grandstands, and Bleachers the minimum row spacing of seats without backrest in open air stand
600
650
700
800
Foundations – not < _______ mm below the grade, may encroach ______mm into public sidewalk areas.
600, 500
600, 400
500, 300
600, 600
Footings must be at least _______ m below grade along national roads, may project not >______mm beyond Property line.
2.4, 400
2.5, 300
2.3, 400
2.4, 300
A permanent roofed structure above a door attached to and supported by the building and projecting over a wall or sidewalk.
Balconies
Awnings
Canopies
Change in use or occupancy.
Alteration
Addition
Conversion
Work done on any damaged/deteriorated portion of bldg.
Alteration
Renovation
Repair
Window openings for room must have at least _____% of the floor area with a minimum area of _____ sq.m.
20, 1
10, 2
10, 1
20, 2
Window openings for baths and toilets must have at least ____ of the floor area with a minimum area of _____ sq.mm
1/20, 250
1/30 240
1/20, 240
1/10, 240
Secondary bldg. Located w/in the same premises the use of incidental to that main bldg.
Ancillary Building
Extra Building
Expanded Structure
Which are not included for the requirements for building permit?
The use or occupancy of proposed work
A description of work to be covered by the permit
Description and ownership of the lot – TCT
Tax Documents
What type of construction is for wood construction with fire resistant materials 1 – Hour Fire Resistive Rating?
Type II
Type III
Type IV
Type I
What type of construction is for wood construction?
Type II
Type III
Type I
Type IV
What type of construction is for wood and masonry construction with fire resistant materials 1 hour fire resistive rating?
Type II
Type IV
Type III
Type I
What type of construction is for steel, iron concrete construction with fire resistant materials 1 hour fire resistive rating
Type V
Type II
Type IV
Type III
Vertical clearance of awning (undermost surface of the awning or GL) is not less than ________m.
3
2.7
2.4
2.8
Ventilation or vent shafts - horizontal cross - section area not less than _____sq.m per meter height of shaft
0.15
0.10
0.20
0.12
This is where all on site work done
Office
Construction
Sa bahay ng mama mo
DPWH
The width of a stair way if the occupant load of more than 50 shall not be less than ____m
1.2
1.1
1
1.5
The width of a stairway if the occupant load of less than 50 shall not be _____m
0.90
1
0.80
0.40
The slope of an exit passage way will have a maximum slope of
1/8
1/10
1/15
1/20
The slope of an exit courts will have a maximum slope of
1/8
1/10
1/12
1/5
The size of the room for kitchen must be at least
1.5x2m
1.5x3m
2x3m
1.5x2.1m
The size of the room for human habitation must be at least an area of ____sq.m and _____m minimum distance
6, 2
7,3
6,3
7,2
The size of bathrooms of toilets must be at least an area of _____sq.m and _____m minimum distance
1.2, 1.0
1.5, 0.9
1.2, 0.9
1.3, 0.10
The rating in which a material can withstand fire
Fire respective rating
Fire resistive rating
Fire protective rating
None of the above
The number of exits for mezzanine with 185 sq. M area or more than 18m in dimension will be exits
1
2
3
4
The number of exits for above 1st storey with 10 occupant _______ exits
1
2
3
4
The minimum row space with backrest will be
700
750
850
450
Public Street or alley <______m in width shall be truncated at the corner “Chaflan”
3.4
3.6
3.5
3.7
The maximum rise and run of the stairs will be
200, 200
200, 250
200, 300
250, 250
The headroom clearance for stair will be
2.1m
2.0m
2.5m
3.00m
The general provision of PD 1096 or the national building code of the Philippines are
Safe construction
Adequate environmental safeguards
Maintain building in safe, sanitary and good working conditions
All of the above
The enforcement of PD 1096 on their respective jurisdiction is the
Mayor
Architect
Building Official
City Engineer
The door that will be required if the exit door shall swing to exit travel in hazardous areas with 50 or more occupant load
Swing
Panel
Leaf
Double
The distance between 2 landings in stairs will be a maximum of
3.0 m
3.5 m
3.6 m
4.0 m
The building permit will be null or void if the construction didn’t commence the work in a period of
6 months
12 months
2 years
3 months
The building permit will be null or void if the construction has been abandoned for how many days
30
60
120
80
Systematic dismantling of a bldg in whole or part
Reinstallation
Demolition
Dismantle
Renovation
Stair with a straight run, the landing will be a maximum of _______ m vertical distance
1.2
1.4
1.5
2.0
Spacing of rows of seats from back to back : rows of 46 seats or more (continental)
450 mm
500 mm
520 mm
550 mm
Spacing of rows of seats from back to back : rows of 45 seats or less (continental)
450 mm
500 mm
520 mm
550 mm
Private stairways that serve <10 occupants will be a minimum of _____m
0.60
0.80
0.75
0.70
PD 1096 will be enforced by the secretary of
UAP
PRC
MUNICIPALITY
PUBLIC WORKS
Minimum aisle width if serving only two side
1 m
1.2 m
1.5 m
0.90 m
Minimum aisle width if serving only one side
800
900
700
500
Minimum height of mezzanine floor in meters
1.80 m
2.0 m
1.75 m
1.90 m
Means "installation of components of a building/structure"
Secure
Erection
Site Work
Demolition
Protective fence or canopy shall be removed ____days after protection no longer required.
30
15
20
10
Located partly in one (1) fire zone and partly in another.
High Restrictive Fire Zones
Moderate Restrictive Fire Zones
High Restrictive Fire Hazards
Moderate Restrictive Fire Hazards
In winding stairways, the narrower side of the tread will be __________.
150-250mm
200-300 mm
150-300mm
250-350mm
In qualification for being a building official, you must have a diversified working experience of an architect or engineer for how many years?
6
4
5
7
In qualification for being a building official, you must be registered as a/an __________.
ARCHITECT
ENGINEER
URBAN PLANNER
LANDSCAPE ARCHITECT
A AND B
In qualification for being a building official, you must be a member of an accredited organization of not less than how many years?
2 YEARS
1.5 YEARS
3 YEARS
5 YEARS
How many set of plans and specifications are needed for the requirements of a building permit?
5
4
6
7
How many days will it take for the issuance of building permit?
12 DAYS UPON PAYMENT
15 DAYS UPON PAYMENT
14 DAYS UPON PAYMENT
30 DAYS UPON PAYMENT
Handrails in stairs will be _________ mm.
800-900
700-900
900-1200
600-800
Groups H, I occupancies without seats, line of travel to exit door by an aisle is not less than ______ m.
45
30
60
50
For Protective Nets/Screen the G.I wire gauge must be ________mm mesh _____ net; canvas
16.38 mm / nylon
16.37 mm/ steel
16.39 mm/ nylon
16.38mm/ steel
(For protection of pedestrians during construction or demolition) Fences must be not greater than _____m above grade.
2.3
2.2
2.4
2.5
(For protection of pedestrians during construction or demolition) Canopies must _______m above the railway, live load 600 kg per sq. m.
2.5
2.6
2.4
2.3
(For protection of pedestrians during construction or demolition) The temporary walkway will be at least _____m wide (during construction).
1.2
1.3
1.4
1.5
(For protection of pedestrians during construction or demolition) The capability of supporting a uniform live load of ____ kg per sq. m. for temporary walk way.
600
650
620
. 630
The pedestrian protection railings in the street side of a sidewalk must be at least _____m in height.
1
2
1.2
. 0.90
For exit sign illuminations, the minimum lux equivalent will be:
10.7
10.6
10.8
10.9
For circular stairs that will be used as an exit, the minimum width of run will be greater than ______ mm.
200
250
300
350
For attics, the access will not be greater than _____sq. mm. In diameter, and a minimum clear headroom of ____mm.
600, 800
800, 600
600, 700
700, 800
For 599-999 occupants, how many exit/s is/are needed?
1
2
. 3
4
Which of the following DOES NOT comply with the qualifications to be appointed as Building Official?
Filipino citizen and good moral character
Member of good standing accredited organization
Attended seminar workshop on PD1096 by the DPWH
Atleast 3 years experience in building design and construction
N the determination of the amount of fines to be imposed, which is considered as a less grave violation?
Use or occupancy of building/structure without appropriate certificate of occupancy
Failure to post building permit construction information sign
Excavation left open without any work being done in the site for more than 120 days
Failure to post certificate of occupancy/use/operation
The prescribed amount of fines for violations of the Code for Less Grave Violations is
8,000 pesos
5,000 pesos
3,000 pesos
7,000 pesos
This type of construction involves the use of masonry and wood construction. Structural elements may be any of the materials permitted by the Code provided, that the building shall be one-hour-fire-resistive throughout.
Type III
Type I
Type IV
Type V
To determine the maximum development potential of a lot, the allowable maximum building footprint (in sq.m) divided by the lot area refers on which guideline on building development and controls?
Allowable maximum Building Footprint
Resultant height of the building
Percentage of site occupancy
Setback
The total floor space within the perimeter of the permanent external building walls and also includes building projections which may serve as floors or platforms.
Percentage of site occupancy
Floor to lot area ratio
Building footprint
Gross Floor Area
Required open space left between the outermost face of the building and property line
Sidewalks
Yard
Recreational park
Street
According to the Rule XI - Protection of Pedestrians During Construction Section 1106 Pedestrian Protection, which of the following is not included in the section?
Fences
Railings
Warning signs
None of the above
No point in a building without a sprinkler system shall be more than _____ from an exterior exit door, a horizontal exit, exit passageway, or an enclosed stairway, measured along the line of travel.
30.00 m
50.00 m
45.00 m
60.00 m
The distance between landings of stairs shall not exceed
6.00 m
3.60 m
4.00 m
2.40 m
Every building of four storeys shall be equipped with one or more dry standpipes. What are the factors considered on the installation?
I. Size
II. Number of occupants
III. Siamese connections
IV. Outlets
I. Size
II. Number of occupants
III. Siamese connections
IV. Outlets
I, II and III only
I, II and IV only
I, III, and IV only
All of the above
Fire pumps that will be connected to street main shall not be less than
150.00 m
100.00 m
130.00 m
120.00 m
Fire extinguishing system will be provided for every storey, basement or cellar that shall be used as:
Emergency room
Habitation
Office
Storage area
The excavation made on public property - restored immediately to its former conditions within
48 hours
24 hours
120 hours
60 hours
The maximum dimension of the door leaf width shall be
1.20 m
1.00 m
0.90 m
1.30 m
The maximum distance between sprinklers (center to center) shall be:
1.80 m
3.00 m
2.40 m
2.00 m
The ceiling height for habitable rooms without artificial ventilation from floor finish to ceiling is
3.00 m
2.70 m
2.40 m
2.10 m
The air space requirements for workshop, factories and offices
10.00 cu.m of air space per person
14.00 cu.m of air space per person
16.00 cu.m of air space per person
12.00 cu.m of air space per person
The air space requirements for school classrooms shall be:
1.00 cu.m with 2.00 sqm of floor area per person
14.00 cu.m of air space per person
3.00 cu.m with 1.00 sqm of floor area per person
12.00 cu.m of air space per person
Defined as a movable shelter supported from an exterior of the building which can be retracted, folded, collapsed against the face of the supporting building
Balconies
Yards
Canopies
Awnings
Eaves over required windows not < _____. Minimum over from the side & rear property lines?
300 MM
600 MM
1000 MM
750 MM
Width and Height of doors will be not < _____mm in width, not < ______m in height, opening will be 90 degrees and exit way clear width not < 700mm?
900, 2.1
800, 2.0
900, 2.0
{"name":"Mock Prof Prac Quiz 1", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Welcome to the Mock Prof Prac Quiz 1! Test your knowledge and understanding of professional practice regulations and standards in building construction. This quiz is designed for students and professionals alike, providing a comprehensive overview of essential concepts.Multiple choice questionsFoundational construction principlesBuilding permits and requirementsFire resistive construction ratings","img":"https:/images/course2.png"}