Prof Prac nanaman GRP 3

Create an informative and visually appealing infographic illustrating accessibility standards including parking slots, ramps, handrails, and fire safety in a modern architectural setting.

Accessibility Standards Quiz

Test your knowledge on accessibility standards and regulations with this comprehensive quiz. Designed for professionals and learners alike, it covers important specifications pertaining to parking slots, ramps, door widths, and fire safety.

Perfect for those looking to enhance their understanding of accessibility in buildings, this quiz features:

  • 100 multiple-choice questions
  • Instant feedback on your answers
  • A chance to improve your knowledge of crucial regulations
100 Questions25 MinutesCreated by LearningSpace42
What is the minimum width of accessible parking slots?
3.40 m
3.00 m
3.60 m
3.70 m
What is the minimum width of walkways
2.00 m
1.40 m
1.00 m
1.20 m
Handrails shall be installed at ___ and ___ above steps or ramps.
0.40 m and 0.60
1.00 and 1.06 m
0.90 and 1.00 m
0.90 and 0.70 m
Handrails for protection at great heights may be installed at ___ to _____.
0.40 m and 0.60
1.00 and 1.06 m
1.90 and 1.00 m
1.40 and 1.70 m
Minimum clear width of ramps.
0.60 m
1.00 m
1.20 m
0.80 m
Maximum gradient of ramps.
1:12 m
1:16 m
1:14 m
1:20 m
The length of ramp should not exceed ____ if the gradient is 1:12
7.00 m
6.20 m
6.00 m
5.40 m
Longer ramps whose gradient is 1:12 shall be provided with landings not less than ____
1.20 m
2.00 m
1.70 m
1.50 m
Minimum height of curbs on both sides of ramp
0.20 m
0.03 m
0.10 m
0.90 m
Minimum clear width of doors.
0.80 m
0.71 m
0.60 m
0.90 m
Doors along major circulation routes should be provided with____ made of durable material.
Tactile tiles
Door signages
Kick plates
Handles
Kick plates should be installed at a height of ___ to ___
0.30m to 0.40m
0.50m to 0.60m
0.20m to 0.30m
None of the above
Minimum size of recesses or turnabouts for wheelchairs.
1.40m
1.60m
1.30m
1.50m
Minimum width of a curb cutout
1.40m
1.00m
0.90m
0.60m
Minimum walkway headroom
1.40m
2.00m
1.90m
2.70m
Republic Act known as The Fire Code of the Philippines
RA 9266
BP 344
PD 957
RA 9514
Buildings of such low combustibility that no self-propagating fire therein can occur and that consequently, the only probable danger requiring the use of emergency exits will be from panic, fumes or smoke or fire from some external source.
High Hazard
Low Hazard
Small Hazard
Bio Hazard
Minimum exit door width
0.71 m
0.70 m
0.81 m
0.90m
The time duration that a material or construction can withstand the effect of standard fire test is known as____
Fire Hazard rating
Fire Resistance rating
Heat Duration rating
Heat Conductivity rating
Minimum travel distance from any individual room subject to occupancy by not more 6 persons.
6 m
10 m
15 m
7.5 m
Fire escape handrails shall not be less than ___.
.76 m
.10 m
.65 m
1.0 m
Minimum width of any corridor or passageway serving as a required exit.
1.6 m
1.0 m
1.12 m
1.20 m
Minimum height of guard rail.
0.91 m
1.0 m
0.85 m
0.95 m
Maximum height of guard rail.
0.91 m
1.06 m
1.02 m
0.95 m
Travel distance to an exit with fire sprinkler system
91 m
16 m
10 m
61 m
Travel distance to an exit without fire sprinkler system
91 m
46 m
10 m
61 m
Number of exits for place of assembly for 1000 occupants
4 exits
5 exits
6 exits
7 exits
Minimum clear width for existing stairs
915 mm
810 mm
700 mm
950 mm
Minimum width for new stairs with less than 200 occupants.
1120 mm
1500 mm
900 mm
1200 mm
Minimum width for new stairs with more than or equal to 200 occupants.
1420 mm
1500 mm
900 mm
1200 mm
Minimum number of apartment units requiring fire alarm system
12
15
9
10
Minimum dimension of a rescue window for educational occupancies
300 mm
500 mm
550 mm
600 mm
Maximum slope for aisles for public assembly structures.
(1:7) 14%
(1:8) 12.5%
(1:9) 11%
(1:6) 16%
Minimum width for fire escape for existing stairs
600 mm
500 mm
559 mm
669 mm
The time duration that a material or construction can withstand the effect of standard fire test is known as
Water resistance rating
Fire resistance rating
Material resistance rating
Fire duration rating
Buildings or structures 15 meters or more in height.
Medium rise building
Skyscrapper
Low rise building
High rise building
A continuous passageway for the transmission of air.
Vent
Air condition
Duct Systems
Louvers
Minimum height of fence for a lumber yard for exterior storage of lumbers.
1.80 m
1.70 m
1.90m
1.60 m
Maximum distance of travel from the high hazard area to an exit.
20 m
21 m
22 m
23 m
Minimum stair width for a class B stair serving an occupant load of less than 50.
900 mm
910 mm
920 mm
930 mm
Minimum stair width of accessible ramps
1.20 m
1.50 m
2.00 m
1.80 m
Accessible ramps minimum gradient
1:8
1:10
1:12
1:14
___ long extension of handrail shall be provided at the top and bottom of ramps
300 mm
330 mm
380 mm
360 mm
Handrails should be installed @__, __ above stairs or ramps
900mm; 800 mm
910; 800 mm
920; 700 mm
900; 700 mm
If there are 501-1000 number of parking slots, how many are allotted for pwd?
4% of the space
3% of the space
2% of the space
1% of the space
Min. Width for pwd parking slot
3.60 m
3.70 m
3.80 m
3.90 m
A walkway min. Clear width to be provided between front ends of parked cars
1.20 m
1.50 m
2.00 m
1.80 m
Parking slots for pwd shall never be located @ __
In front of the building
Near entance
Sidewalk
Ramped or sloping areas
International color for pwd symbol
Black and yellow
Blue and white
Yellow and white
Green and white
The max. Height of signs (graphics, text, and Braille) on walls and doors should be installed from finished floor to the center of the sign
1.50 m
2.00 m
1.25 m
1.90 m
Maximum height between landings of a fire staircase
2.10 m
2.66 m
3.66 m
3.10 m
Minimum width of a fire staircase
600 mm
750 mm
1000 mm
1200 mm
Minimum tread, exclusive of nosing of a fire staircase
25 cm
23 cm
30 cm
28 cm
All fire escape shall have handrails on both sides, not less than
Seventy six centimeters (76 cm) not more than one hundred seven centimeters (107 cm) high
Seventy six centimeters (80 cm) not more than one hundred seven centimeters (90 cm) high
80 cm
90 cm
Fire exit Ladders shall be constructed of what material
Plastic
Iron, of steel
Concrete
Wood
Every exit shall have the word "EXIT" in plainly legible letters not less than
30 cm
32 cm
(20 cm) high with the principal strokes of letters not less than (25 mm) wide
(15 cm) high with the principal strokes of letters not less than (19 mm) wide
No point within a building, requiring dry standpipes, shall be more than _______ travel distance from a dry standpoint outlet connection
28 m
35 m
30 m
40 m
The size of the standpipe shall have a diameter of at least _____
102 mm
100 mm
120 mm
112 mm
Wet standpipes shall be located so that all portions of the buildings are within _____ of a nozzle attached to twenty two meters (22 m) of hose.
12m
10m
6m
8m
A continuous and unobstructed route of exit from any point in a building to a public way?
Means of Egress
Means of Exit
Means of Entry
Means of Access
Minimum number of apartment units requiring fire alarm system?
22
12
15
10
Maximum force in kilograms required for a panic hardware (in kilograms)?
12 kg
10 kg
8kg
7kg
Maximum distance of travel from the high hazard area to an exit (in meters)?
23m
25m
40 m
15 m
A class of fire with flammable liquid and gasses
Class A
Class B
Class C
Class D
AN ACT ESTABLISHING A COMPREHENSIVE FIRE CODE OF THE PHILIPPINES, REPEALING PRESIDENTIAL DECREE NO. 1185 AND FOR OTHER PURPOSES
RA 9514
PD1096
BP344
BP220
At least ____ exits of the above types, remote from each other, shall be provided for each floor or fire section of the building.
2
3
1
4
Exit access travel shall be permitted to be common path not exceeding _______
30m30m
25m
35m
40m
No exit or exit access shall contain a corridor, hallway, or aisle having a pocket or dead end exceeding ________
5m
6m
7.5m
10m
Between any room door intended as exit access and an exit shall not exceed_________
25m
30m
35 m
40 m
Between any point in a room and an exit shall not exceed_______
46m
20m
26m
35m
Any point in a sleeping room to the door in that room shall have a maximum travel distance of______
12m
10m
15m
12.5m
Smoke detectors shall not be required in sleeping rooms with ___ or fewer occupants
4
12
16
8
Every storey used for sleeping by residents, or any other storey with an occupant load of ______ or more persons, shall be subdivided into compartments by means of smoke barrier.
50
30
20
60
A building separated from the resident housing area by 2 – hour fire resistance rating or _________
14 meters of open area
22 meters of enclosed area
22 meters of open area
14 meters of enclosed area
Corridors, other than those in within individual guest rooms or individual guest suites, shall be of sufficient width to accommodate the required occupant load and shall not be less than _______
110 cm
112 cm
120 cm
125 cm
Unhindered, without obstructions to enable disabled persons free passage or use of the facilities
Freeway
Barrier-free
Innisfree
Freestyle
A raised rim of concrete, stone or metal which forms the edge of street, sidewalk, planted area, etc
Curve cut-out
Curb cut-out
Curb cat-out
Curb
A break in the sidewalk or traffic island provided with an inclined surface to facilitate mobility of wheeled chairs, carriages and other similar conveyance
Curve cut-out
Curb cut-out
Curb cat-out
Curb
Identification for designated seats.
International Symbol of Access
International Seat Number
International Symbol of Design
International
A strip fastened to the floor beneath a door, usually required to cover the joint where two types of floor materials meet; may provide weather protection at exterior doors.
Stripper
Vestibule
Threshold
Tape
______ a small entranceway or transitional space from the exterior to the interior of a building and opens into a larger space.
Doorway
Secret door
Vestibule
Portal
______ is preferred than projected nosing.
Slanted nosing
Vertical nosing
Horizontal nosing
Nosing balasi
_______ pertaining to the measurement of the human body
Anthropologetic
Anthropometric
Vital Statistics
Dimension
_______ an exit, or a means of going out.
Tres
Ingress
Tetris
Egress
_______ the degree of inclination of a sloped surface expressed as a percentage or ratio.
Gradient of Ramp
Ramp Model
Ramp Post
Gradient of Color
_______ a drawing, painting, diagram, engraving, etching or other similar illustrations on which a single glance conveys a given message; a visual aid.
Graphic Arts
Graphic Design
Architectural Graphics
Graphic Sign
Meaning of FALAR.
Fire and Land Safety Assesment Report
Fire and Light Safety Assesment Report
Fire and Lifeline Safety Assesment Report
Fire and Life Safety Assesment Report
Meaning of FSES.
Food Safety Evaluation System
Fire Safety Enforcement Section
Fire Safety Emergency Section
Father Subido Elementary School
Meaning of AIR.
Annual Information Return
Am I Right
Annual Infrastructure Report
After Inspection Report
FALAR 1 is signed by ______?
Contractor and CM
Building Administrator
Architect and FSP
Project Manager
FALAR 2 is signed by ______?
Contractor and CM
Building Administrator
Architect and FSP
Project Manager
FALAR 3 is signed by ______?
Contractor and CM
Building Administrator
Architect and FSP
Project Manager
Pre-requisite of FALAR 1.
Occupancy Permit
Sanitary Permit
Business Permit
FSEC (Fire Safety Evaluation Clearance)
Pre-requisite of FALAR 2.
Occupancy Permit
Sanitary Permit
Business Permit
FSEC (Fire Safety Evaluation Clearance)
Pre-requisite of FALAR 3.
Occupancy Permit
Sanitary Permit
Business Permit
FSEC (Fire Safety Evaluation Clearance)
Hazard Contents Classification with low combustibility contents
Low Hazard
Moderate Hazard
Average Hazard
High Hazard
Hazard Contents Classification that is liable to burn in moderate rapidity. Gives considerable volums of smoke.
Low Hazard
Moderate Hazard
Average Hazard
High Hazard
Hazard content classification that is liable to burn in extreme rapidity. May be poisonous and explosive.
Low Hazard
Moderate Hazard
Average Hazard
High Hazard
The size of the standpipe shall have a diameter of at least _____
102 mm
100 mm
120 mm
112 mm
A break in the sidewalk or traffic island provided with an inclined surface to facilitate mobility of wheeled chairs, carriages and other similar conveyance
Curve cut-out
Curb cut-out
Curb cat-out
Curb
{"name":"Prof Prac nanaman GRP 3", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Test your knowledge on accessibility standards and regulations with this comprehensive quiz. Designed for professionals and learners alike, it covers important specifications pertaining to parking slots, ramps, door widths, and fire safety.Perfect for those looking to enhance their understanding of accessibility in buildings, this quiz features:100 multiple-choice questionsInstant feedback on your answersA chance to improve your knowledge of crucial regulations","img":"https:/images/course7.png"}
Powered by: Quiz Maker