Chapter 6

The code requirement for an adequate supply of potable running water is for:
Safety or sanitation
Protection of trap seals
Water cooled equipment
Hydronic system
The primary reason for installed backflow prevention assemblies is to:
Prevent excessive pressure
Prevent mixing of hot and cold water
Prevent pollution or contamination of the potable water system
Prevent scalding
Ball cocks in water closet tanks shall be installed so that the critical level of the water inlet is above the full opening of the overflow pipe, at least:
1/2 inch
1 inch
3 inches
6 inches
PEX tubing shall not be installed within the first___of piping connected to a water heater
12 inches
18 inches
24 inches
36 inches
Each outlet on a non-potable water line which may be used for drinking purposes shall be posted:
Danger-processed water
Danger-contaminated water
Danger-Poluted water
Caution-non potable water-do not drink
The piping material not approved in the code for water piping located inside a building is
Brass
CPVC
Asbestos cement
PEX
All malleable iron water fittings shall be
2 inches or smaller
Galvanized
Flanged
Removed
Water piping systems shall be designed on the basis of the:
Maximum pressure
Minimum Pressure
Avereage residual
Average service pressure
Copper water type "M" may be installed withing a building:
Below slab only
Above ground only
For cold water only
If it is wrapped
Immediately ahead of each water supplied appliance and each slip joint or non-mettalic water supply connection is required a:
Control valve
Check valve
Backwater valve
Solenoid valve
A water piping system with a pressure of 110 psi will require a:
Reduced pressure backflow device
Extra heavy pipe and fittings
Pressure regulator and strainer
Pressure relief valve
Any water heater connected to a separate storage tank with valves between the heater and tank shall be provided with a:
Full way valve
Full way gate valve
Water pressure regulator
Water pressure relief valve
Combination temperature and pressure relief valves shall be installed:
Based on its listing requirements and manufacture's instruction
With 3 inches to 6 inches of the water heater
In Lieu of pressure relief valves
On all non-storage type water heaters
Building supplied shall be no smaller than that required for the installation and in no case smaller than:
1/2 in
3/4 in
1 in
2 in
Copper tubing used for water under a concrete slab within a building shall be:
Installed with brazed joints with cast brass fittings
Protected with a factory applied coating
Installed without joints where possible
Installed with type "K" copper tube with brazed joints
CPVC water piping may be used for hot and cold water distribution systems:
In residences only
Within a building
Below ground only
Above ground only
Flexible corrugated connectors of copper or stainless steel for water heaters connections shall be limited to
12 inches
18 inces
24 inches
36 inches
Unions shall be installed in a water supply system within 12 inches of
A control valve
A house valve
Transition fittings
Regulating equipment
The type of valve required on a building supply to any building is a:
Full way valve
Corportation Valve
Butterfly Valve
Globe Valve
Mechanical devices installed to absorb water hammer shall be:
Accessible
Readily accessible
Concealed
Exposed
Atmosperic type vacuum breakers shall not be subjected to:
Back pressure
Hot Water
Used in laboratory
Intermittent use
Each pressure relief valve instaleld inside of the building shall have a:
Full size drain extended to outside
Check valve to prevent backflow
Trapped drain line
Drain which terminates 30 inches or more above grade
Hard drawn copper tubing, marked with a blue stripe, is referred to as:
Type "K"
Type "L"
Type "M"
Type "DWV"
The color stripe on type "DWV" hard drawn copper tubing is:
Green
Blue
Red
Yellow
Flaring tools are used to make joints for:
Hard type "K" copper tubing
Soft copper water tubing
Yellow brass water piping
Aluminum water piping
{"name":"Chapter 6", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"The code requirement for an adequate supply of potable running water is for:, The primary reason for installed backflow prevention assemblies is to:, Ball cocks in water closet tanks shall be installed so that the critical level of the water inlet is above the full opening of the overflow pipe, at least:","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}