Test your knowledge on electrical protection systems with our comprehensive quiz! With 51 challenging questions, you'll delve into concepts such as differential protection, distance protection characteristics, and operational practices. This is an excellent opportunity for professionals and students to assess their understanding and learn more about the intricacies of electrical engineering.
- 51 questions covering key protection fun
ctions. - Designed for students, certification seekers, and industry professionals.
- Enhance your knowledge in a critical field of engineering.
Functia de protectie de supraveghere a arderii sigurantelor ( RFUF) este necesara pentru:
1. Accelerarea functionari protectiei de distanta la scaderea tensiunii
2. Evitarea declansarilor eronate a protectiei de distanta atunci cand avem deranjamente in circuitele secundare de tensiune
3. Evitarea declansarilor eronate a protectiei de distanta atunci cand avem deranjamente in circuitele secundare de curent
Functia de teleprotectie are ca efect:
1. Declansarea rapida a tuturor defectelor de pe linie
2. Declansarea selectiva a defectelor
3. Creste sensibilitatea protectiilor aferente
Protectiile diferentiale isi bazeaza fun ctionarea pe:
1. Legea lui Ohm
2. Legea a doua a lui Kirchhoff
3. legea 1 Kirchhoff
Poate fun ctiona o instalatie RAR monofazat la un intreruptor trifazat:
1. nu
2. da
3. Da cu ajustarea pauzei de RAR
Zona protejata de protectia diferentiala de trafo este:
1. Zona cuprinsa in interiorul cuvei trafo si a trecerilor izolante ale trafo
2. Zona cuprinsa in interiorul cuvei trafo
3. Zona cuprinsa intre transformatoarele de curent ale celulelor trafo
Diferentierea dintre un scurtcircuit si o pendulatie se face prin
1. La scurtcircuit impedanta antra in poligonul treptel 1 a protecuel de distanta Si ramane acolo. Or la pendulabe nsa in poligonul treptel 1 s, tese pe aceeas, parte a polgonulut
2. La scurtcircuit impedanta antra in polgonul de demarai si ramane acolo, la,- la pendulane infra in polgon si iese pe partea opusa a poligonulut
3. La scurtcircuit impedanta intra in poligonul de demaraj si ramane acolo, iar la pendulatie intra in poligon si iese pe aceeasi parte a pologonului
Daca un osciloperturbograf are rata de esantionare egala cu 1 ms atunci cate masuratori se efectueaza intro perioada T a marimiior sinusoidale cu frecventa 100 Hz:
1. 50
2. 20
3. 10
Se poate efectua conectarea unui intreruptor daca:
1. Diferenta amplitudinilor tensiunilor pe poli intreruptorului este sub un prag setat
2. Diferenta amplitudinilor tensiunilor pe poli intreruptorului este mai mare decal un prag setat
3. Diferenta amplitudinilor tensiunilor pe poli intreruptorului sa fie zero
Caracteristica de temporizare a unei protectii de distanta este:
1. O caractristica dependenta curent - timp
2. O caracteristica in trepte de timp predefinite de Ia valori mici Ia valori mari
3. O caracteristica in trepte de timp predefinite de Ia valori marl Ia valori mici
Desensibilizarea protectiei de distanta fata de suprasarcini se face prin:
1. Realizarea unui decupaj in caracteristica de demaraj
2. Realizarea de caracteristici de demaraj cu valori mai mici atat pentru rezistenta cat si reactanta
3. Nu este necesara aceasta desensibilizare
Desensibilizarea protectiei de distanta fata de rezistenta de arc se face prin:
1. Realizarea unei temporizari mai mari
2. Nu este necesara aceasta desensibilizare
3. Realizarea de caracteristici de functionare separate pentru bucle de defect faza - pamat si bucle faza - faza
Functia de sincronizare sau control al sincronismului (RSYN, 25) se aplica:
1. atat Ia conectarea manuala cat si Ia conectarea prin RAR a intreruptoarelor
2. doar Ia conectarea manuala
3. doar Ia conectarea prin RAR a intreruptoarelor
Rata de esantionare aferenta unui osciloperturbobraf digital este:
1. Timpul de inregistrare a marimilor de regim normal
2. Timpul intre doua masuratori consecutive
3. Timpul de inregistrare programat
Protectie la conectarea liniei pe defect /Switch On To Fault (PIOC ,50HS[SOTF]) este in general:
1. O protectie maximala de curent de faza instantanee si nedirectionata
2. O protectie de impedanta
3. O protectie maximala de curent de faza instantanee si directionata
Protectia diferentiala de linie este o protectie selectiva :
1. nu
2. Doar daca este insotita si de o protectie de distanta
3. da
Protectie maximala de tensiune temporizata (PTOV , 59) este necesar a fi folosita in combinatie cu:
1. Functia de RAR
2. Se foloseste intodeauna ca functie independenta de protectie
3. Functia de teleprotectie
Care din afirmatiile de mai jos este corecta:
1. Protectie maximala de curent de faza instantanee (PIOC , 50) se utilizeaza de preferinta in retele radiale
2. Protectie maximala de curent de faza instantanee (PIOC , 50) se utilizeaza doar in in retele radiale
3. Protectie maximala de curent de faza instantanee (PIOC , 50) nu se utilizeaza in retele buclate
Functia de protectie de supraveghere a arderii sigurantelor ( RFUF) fun ctioneza si la:
1. Aparitia regimurilor anomale de functionare
2. Aparitia unui scurtcircuit in retea pe alt element de retea decal cel protejat de protectie
3. Declansarea sigurantelor automate aferente grupului de masura de tensiune al celulei elementului protejat
O protectie de distanta numerica masoara:
1. Doar reactanta in locul de montare a terminalului
2. Atat rezistenta cat si reactanta in locul de montare a terminalului
3. Modulul impedantei in locul de montare a terminalului
Protectie maximala de curent de faza instantanee (PIOC , 50) fun ctioneaza daca:
1. Curentul pe orice faza depaseste o valoare reglata si se mentine crescut o perioada de timp
2. Curentul pe orice faza depaseste o valoare reglata
3. Curentul creste peste o anumita valoare reglata pe toate fazele
Daca conectam un intreruptor in cadrul unui sistem cu frecventa unica atunci diferenta de faza a celor doua tensiuni are o valoare:
1. constanta
2. Variabila de la 0 la 360 grade
3. Egala cu zero
Pendulatiile de putere reprezinta:
1. Un regim permis doar pe Iiniile electrice aeriene
2. Un regim de defect
3. Un regim anormal de functionare a sistemului
23. Functia de teleprotectie colaboreaza cu protectia diferentiala de bare:
1. da
2. Doar daca protectia diferentiala de bare are implementat criteriul de declansare doar a celulelor la care a demarat protectia
3. nu
24. Protectia de distanta a unui element de retea:
A) poate sa declanseze la suprasarcina
B) nu declanseaza niciodata la suprasarcina
C) poate declansa la suprasarcini doar daca acestea au ca sens de circulatie de la elementul protejat catre bara
25. Protectia maximala de tensiune temporizata (PTOV , 59) se utilizeaza:
A) 1. In retelele de medie tensiune cu neutrul izolat ca urmare a supratensiunilor care apar la puneri la pamant
B) 2. Doar la unitatile de transformare
C) 3. In retelele de inalta tensiune
26. Caracteristicile de actionare t= f(I) a protectiei maximale de curent de faza temporizata (PTOC , 51) pot fi:
A) 1. Tot timpul combinate
B) 2. Doar independente
C) 3. dependente. Independente sau combinate
27. La RAR cu doua cicluri de RAR putem avea un RAR ciclu 1 nereusit :
A) 1. da, daca defectul este persistent
B) da
C) nu
28. Functia de protectie de supraveghere a arderii sigurantelor ( RFUF) blocheaza fun ctionarea protectiei de distanta daca:
A) 1. Daca avem tensiune homopolara fara sa avem curent homopolar
B) 2. Daca avem atat tensiune homopolara cat si curent homopolar
C) 3. Daca avem curent homopolar fara sa avem tensiune homopolara
29. Treapta 1 a DRRI este o treapta:
A) 1. Reglabila in functie de tipul de element protejat
B) 2. rapida
C) 3. temporizata
30. La o protectie maximala de curent de nul directionala (PDEF , 67N) directia este sesizata prin masurarea unghiului dintre:
A) 1. Curentul homopolar si tensiunea homopolara
B) 2. Curentul fazei defecte si tensiunea fazei defecte
C) 3. Curentul fazei defecte si tensiunea de linie a fazelor sanatoase
31. Functia de protectie de supraveghere a arderii sigurantelor ( RFUF) are ca efect:
A) 1. Blocarea protectiei de distanta
B) 2. Declansarea intreruptorului elementului protejat
C) 3. Reanclasarea intreruptorului elementului protejat dupa o declansare eronata
32. Daca avem o instalatie RAR care fun ctioneaza doar pe RAR monofazat atunci:
A) 1. Nu este necesar a verifica conditiile de sincronism
B) 2. Conditiile de sincronism trebuie verificate la orice tip de RAR
C) 3. Este obligatorie verificarea conditiilor de sincronism
33. Daca conectam un intreruptor intre doua sisteme cu frecvente diferite atunci diferenta de faza a celor doua tensiuni are o valoare:
A) 1. Variabila de la 0 la 360 grade
B) 2. constanta
C) 3. Egala cu 0
34. Protectie maximala de curent de nul instantanee (PIOC , 50N) este o protectie sensibila?
A) nu
B) da
C) 3. Doar la protejarea liniilor electrice aeriene
35. Controlul directiei la protectia maximala de curent de faza directionala (PDOC, 67) se efectueaza prin masurarea defazajului dintre curentul de faza si tensiunea de linie dintre celelalte doua faze (schema de alimentare de 90?) din urmatorul rationament :
A) 1. intr-un timp cu atat mai mic cu cat defectul este mai aproape
B) 2. instantaneu Ia sesizarea unui defect in retea
C) 3. intr-un timp invers proportional cu distanta Ia care a avut loc defectul
36. Protectie la conectarea liniei pe defect /Switch On To Fault (PIOC ,50HS[SOT9) este o protectie:
A) 1. Se activeaza doar de catre personalul operativ sau cel de dispecer
B) 2. Care este activa doar o perioada de timp dupa o inchidere voita a intreruptorului
C) 3. Activa in permanenta
37. Protectia de distanta sesizeaza:
A) 1. Toate tipurile de scurtcircuite de pe elementul protejat
B) 2. Scurtcircuite doar pe directia fata
C) 3. Doar scurtcircuite cu parnantul
38. Treapta 1 a DRRI se face prin:
A) 1. Retransmiterea impulsului de declansare la toate intreruptoarele de pe bara pe care se afla intreruptorul de baza
B) 2. Retransmiterea impulsului de declansare la toate intreruptoarele din statie
C) 3. Retransmiterea impulsului de declansare pe bobina a doua de declansarea a intreruptorului
39. La o protectie maximala de curent de nul directionala (PDEF , 67N) directia este sesizata prin masurarea unghiului dintre:
A) 1. Curentul homopolar si tensiunea homopolara
B) 2. Curentul fazei defecte si tensiunea de linie a fazelor sanatoase
C) 3. Curentul fazei defecte si tensiunea fazei defecte
40. Protectie maximala de curent de nul directionala (PDEF 67N) este o protectie sensibila?
A) 1. Doar la protejarea Iiniilor electrice aeriene
B) nu
C) da
41. Protectie maximala de tensiune temporizata (PTOV , 59) se utilizeaza:
A) 1. In retelele de medie tensiune cu neutrul izolat ca urmare a supratensiunilor care apar la puneri la pamant
B) 2. Doar la unitatile de transformare
C) 3. In retelele de inalta tensiune
42. Protectia diferentiala de bare:
A) 1. Sesizeaza doar defecte care apar intre fazele barelor colectoare
B) 2. Sesizeaza defecte in zona barelor colectare cuprinsa intre tranformatoarele de curent ale celulelor racodate la bare
C) 3. Sesizeaza defecte care au loc in statiile de transformare
43. Daca un osciloperturbograf are rata de esantionare egala cu 1 ms atunci cate masuratori se efectueaza intr-o perioada T a marimilor sinusoidale cu frecventa 100 Hz:
A) 50
B) 20
C) 10
44. Data un osciloperturbograf are rata de esantionare egala cu 1 ms atunci cate masuratori se efectueaza intr-o perioada T a marimilor sinusoidale cu frecventa 50 Hz:
A) 20
B) 50
C) 10
45. Controlul directiei la protectia maximala de curent de faza directionala (PDOC, 67) se efectueaza prin masurarea defazajului dintre curentul de faza si tensiunea de linie dintre celelalte doua faze (schema de alimentare de 90?) din urmatorul rationament :
A) 1. Reducerea riscului ca la defecte foarte apropiate de locul de montare tensiunea sa fie foarte apropiata de zero si unghiul dintre ele sa fie masurat cu o eroare foarte mare
B) 2. Deoarece constructori de echipamente numerice au preferat din motive constructive acest lucru
C) 3. Protectia este mult mai rapida in acest caz
46. Protectia diferentiala de linie sesizeaza:
a) 1. Toate defectele de pe linie
B) 2. Doar defecte cu pamantul (cu componenta homopolara)
C) 3. Doar cu defecte polifazate
47. Protectie maximala de curent de nul temporizata (PTOC, 51 N) este o protectie sensibila?
A) 1. Doar la protejarea liniilor electrice aeriene
B) da
C) nu
48. Daca nu exista protectie de capat (End Zone) / (PIOC , 50EZ) atunci
A) 1. Exista riscul functionarii eronate a protectiei diferentiale de bare (PDB)
B) 2. Trebuie ca PDB sa fie retras din exploatare
C) 3. Trebuie realizata o temporizare la PDB
49. Rezistenta de arc la locul de producere a scurtcircuitului poate avea ca efect
A) 1. Incadrarea defectului intr-o treapta a protectiei de distanta
B) 2. Incadrarea defectului intr-o treapta superioara a protectiei de distanta
C) 3. Nu are nici-un efect
{"name":"Chiosa Examen", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Test your knowledge on electrical protection systems with our comprehensive quiz! With 51 challenging questions, you'll delve into concepts such as differential protection, distance protection characteristics, and operational practices. This is an excellent opportunity for professionals and students to assess their understanding and learn more about the intricacies of electrical engineering.51 questions covering key protection functions.Designed for students, certification seekers, and industry professionals.Enhance your knowledge in a critical field of engineering.","img":"https:/images/course5.png"}