MIN H (m) REQD. FOR DOORS IN THE BUILDING CODE?
1.80
1.90
2.00
2.10
FLOOR WITH OCCUPANT LOAD OF 700 SHALL HAVE AT LEAST HOW MANY EXITS?
2
3
4
5
FENCES SHOULD BE INSTALLED AROUNG THE CONTRUCTION OR DEMOLITION SITE. MIN H REQD. FOR THE FENCE?
2
2.4
4
3.6
MIN DEPTH OF THE ELEVATOR PITS?
1000
600
800
850
MAX INCLINATION OF AN ESCALATOR
25 DEG FROM HORIZONTAL
24 DEG FROM VERTICAL
30 DEG FROM VERTICAL
30 DEG FROM HORIZONTAL
FOR PROTECTION OF PEDESTRIANS, WHAT WILL BE REQD. WHEN THE DISTANCE BETWEEN THE OFB AND THE INNER EDGE OF THE SIDEWALK IS EQUAL TO 75% OF THE BUILDING HEIGHT?
FENCE ONLY
CANOPY ONLY
FENCE AND CANOPY
FENCE,CANOPY, AND SAFETY NET
MIN WIDTH OF A SINGLE-LOADED AISLE
600
750
800mm
1200MM
Min thickness of A GLASS PANEL MEASURING 2.50 X 2.50.
8 mm
10mm
12mm
15mm
MIN DISTANCE REQD FROM A MAJOR ROAD INTERSECTION AND THE INGRESS POINT OF A TRAFFICE GENERATING BUILDING.
25m
50M
75m
100m
What is the MIN AREA FOR HABITABLE ROOMS ACCORDING TO THE NBCP?
1.20
3.00
6.00
12.00sqm
IF THE DISTANCE BETWEEN THE OUTERMOST FENCE OF THE BUILDING AND THE INNER EDE OF THE SIDEWALK IS EQUAL TO THE BUILDING HEIGHT, WHAT IS REQD?
FENCE ONLY
FENCE AND CANOPY
FENCE,CANOPY,AND NET
FENCE,AND TEMPORARY WALKWAY
THE MAX. NUMBER OF PERSONS THAT MAY BE ALLOWD TO OCCUPY A PARTICULAR BUILDING OR SPACE
MAX. OCCUPANCY
BUILDING LOAD
OCCUPANT LOAD
TOTAL OCCUPANCY
WHAT IS THE MAX. NUMBER OF SEATS BETWEEN Two AISLES?
7 Seats
10 Seats
14 seats
30 seats
What IS THE MAX. NUMBER OF SEATS BETWEEN A WALL AND AISLE?
7 SEATS
10 SEATS
14 SEATS
30 SEATS
WHAT IS THE MIN. CEILING HEIGHT REQD. FOR THE SEVENTH FLOOR OF A NATURALLY-VENTILATED BUILDING?
1.8 m
2.10M
2.40M
2.70 M
WHAT IS THE MIN. AREA FOR A HABITABLE ROOMS, ACCORDING TO THE NBCP?
1.20 sqm
3 sqm
6 sqm
12.00 sqm
MIN WIDTH OF A SINGLE-LOAD AISLE?
600mm
750mm
800mm
1200mm
MIN. THCKNESS OF A GLASS PANEL MEASURING 2.50 X 250
8mm
10mm
12mm
15mm
MIN H REQD. FOR DOORS IN THE BUILDING CODE?
1.8m
1.90m
2.0m
2.10m
OCCUPANT LOAD FACTOR FOR HOTELS, ACCORDING RULE 12?
28 sqm.
18.60 sqm.
8.40 sqm.
1.80 sqm
MIN VERTICAL CLEARANCE FROM THE BOTTOM OF A SIGNAGE T AN ARCADED SIDEWALK
6m
3m
5m
4m
An integration piping system connected to a source or extinguishing agent suppressed fires when actuated by its automtic detecting device
Standpipe system
Automaic Fire Suppression system
Fire extinguisher
Fire hose
Max width of door jamb
There is no max width of door jamb
800mm
900mm
1200mm
Standard length of a fire hose
12m
16m
20m
23m
ACCORDING TO NBCP, MAX SPEED F ESCALATORS IS
90 FT/MIN
120 FT/MIN
36 FT/MIN
38 FT/MIN
FOR AGRICULTURAL AREAS, NBC REQUIRED AT LEAST___ OF EASMENT FOR EACH SIDE OF THE WATERWAT
3.00m
10.00m
20.00m
40.00m
FOR URBAN AREAS, NBC REQUIRED AT LEAST___ OF EASMENT FOR EACH SIDE OF THE WATERWAT
3.00m
10.00m
20.00m
40.00m
What is the min size of a classroom for 30 students and 1 teacher, according to the occupant load factors in rule 12 of the building coed
54 sqm
55.80 sqm
138 sqm
142.60 sqm
PARKING SLOTS FOR PWD SHALL NEVER BE LOCATED AT RAMPED/SLOPING AREAS
True
False
WHAT DO YOU CALL THE TACTILE WRITING SYSTEM USED BY PEOPLE WHO ARE VISUALLY IMPARED THAT SHALL BE INCORPORAETED IN SIGN INDICATING PUBLIC PLACES AND SAFETY ROUTES
BRAILLE
BARRLE
BRAELE
BRAELLI
GROUP 5 CLASSIFICATION
ANCILLARY
RESIDENTIAL
COMMERCIAL
INSTITUTIONAL
LETTER A STANDS FOR ____ IN ARCHI FEATURES AND FACILITEIS IN THE BP344
STAIRS
WASHROOMS
ESCALATORS
LADDER
URINALS SHOULD HAVE AN ELONGATED LIP OR THROUGH TYPE; MAX H OF THE LIP SHOULD BE
450MM
380mm
480mm
500mm
LETTER B STANDS FOR ___ IN ARCHI FEATURES AND FACILITIES IN THE BP344
Stairs
Corridors
Walkways
Drinking fountains
IT SHALL BE PROVIDED TO GUIDE PERSON WITH VISUAL IMPAIRMENTS
TACTILE MAPS
Signages
Braille
MIN.TURNING SPACE OF A WATER CLOSET STALLS IS?
2.50 sqm
2.25 sqm
2.00 sqm.
1.50sqm
D STANDS FOR ___ IN THE ARCHI FEATURES AND FACILITIES IN THE BP344
Doors
Doors and entrances
DAMO
DOOOOORS SHIT
GROUP 3 IN CLASSIFICATION OF OCCUPANCY IS ______
RESIDENTIAL
RESIDENTIAL,HOTELS,APARTMENTS
EDUCATIONAL AND INDUSTRIAL
INSTITUTIONAL
GROUP 2 CLASSIFICATION OF OCCUPANCY IS
RESIDENTIAL
COMMERCIAL AND INDUSTRIAL
LIGHT INDUSTRIAL
COMMERCIAL
MAX H OF LAVATORIES SHOULD BE ___
.90 m
.70m.
.60 m
.80m
Toilet DOORS SHALL BE DESIGNED TO OPEN INWARDS S THAT IT WOULD BE EASIER FOR A RESCUER TO ENTER A TOILET CUBICLE IF A PERSON HAS FALLEN AND IS LYNG BEHIND THE DOOR
True
False
Lavatories VERTICAL CLEARANCE IS AT LEAST _____
.70m - .90m
.60m-.70m
.50m-.70m
.65m -.75m
ACCESSIBLE ELEVATORS SHOUBLE BE LOCATED FROM THE ENTRANCE AND SHOULD BE EASY TO LOCATE WITH THE AID OF SIGNS OF NOT MORE THAN 30.00m
True
False
WHAT IS THE MIN STAIR WIDHT REQD IF THE OCCUPANT LOAD IS 15?
750mm
900mm
1100mm
1200mm
MIN WIDTH OF STAIRS FOR OCCUPANT LOAD GREATER THAN 10, ACCORDING TO NBCP
.75m
.90m
1.10m
1.50m
{"name":"PROF PRAC", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"MIN H (m) REQD. FOR DOORS IN THE BUILDING CODE?, FLOOR WITH OCCUPANT LOAD OF 700 SHALL HAVE AT LEAST HOW MANY EXITS?, FENCES SHOULD BE INSTALLED AROUNG THE CONTRUCTION OR DEMOLITION SITE. MIN H REQD. FOR THE FENCE?","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}