Weekly Call Quiz 3-4

Create a professional and engaging illustration of medical gas systems, featuring pipes, valves, pressure gauges, and healthcare professionals working in a hospital environment.

Medical Gas Systems Knowledge Quiz

Enhance your understanding of medical gas systems with our comprehensive quiz. Designed for professionals in the healthcare field, this quiz covers essential regulations, safety measures, and technical standards essential for maintaining medical gas systems.

Test your knowledge on key topics, including:

  • Check valves and backflow prevention
  • Medical gas piping and intake standards
  • Safety protocols for cylinder storage
  • Maintenance qualifications and inspection processes
16 Questions4 MinutesCreated by InspectingValve304
Check valves used to prevent the back flow of gas from one section of the pipe to the other shall be composed of what?
Brass
Bronze
Stainless Steel
Brass or Bronze
Bronze or Stainless Steel
All of the above
The minimum SLPM flow of critical care nitrogen terminals shall be what?
100
160-185
50
140
170 for 3 seconds
When multiple vacuum pumps exhaust into one common exhaust line, that line must?
Comply with the copper tubing requirements of medical gases
Sized in a manner to prevent back flow
Sized in a manner to prevent back pressure
Common exhaust is not acceptable
Which of the following best defines a NFPA99-2015 Category 2 facility.
Outpatient clinic
Cancer oncology facility where patients recieve chemo
Eye doctor outpatient surgery center
Dentist office
None of the above
WAGD inlets need to have a primary check valve and are not required to have a secondary check valve.
True
False
The labeling of medical gas piping will allows consist of the gas name or ?
Gas color
Chemical symbol
Operating pressure
Directional flow arrows
Medical air intake piping shall be which of the following ?
ASTM B 819 Copper
ASTM B 88 Copper
Stainless Steel
Any of the above
Central supply locations for medical gas cylinder shall be kept from reaching temperatures above? (2015 code)
100F
125F
130F
Manufactures Recommendation
Varies with gas
The minimum number of cylinder connections for a mircobulk cryocenic reserve shall be?
There is no minimum
2 connections
3 connections
None of the above
The low possibility of the instrument air system failing because it is duplexed and monitored by an alarm system, allows that specific system to be considers a category 3 piece of equipment.
True
False
Underground medical gas piping must be ran in continous conduit because which of the following reasons?
Because of the backfill material
Piping in contact with water will begin to corrode
Surface pressure from which it is buried under
Personnel do not dig into the pipe line and cause a seperation of pipe
All of the above
None of the above
According to the NFPA99-2012, only an individual with this is allowed to do maintenance and repairs on the medical gas systems.
ASSE 6010 credentialed
ASSE 6040 credentialed
Hospital employee familiar with the equipment
All of the above
None of the Above
Pressure relief valves are used to release excess pressure that has been built up. Pressure relief valves must be made up of what?
Brass
Bronze
Stainless Steel
Brass or Bronze
Bronze or Stainless Steel
All of the above
This installer's test last for ____ at 20% above operating pressure and must be signed off by the AHJ once completed.
10 minutes
Inital pressure test
Final pressure test
24 hours
8 hours
When verifying the functionality of replaced or repaired equipment, the rated accuracy of the pressure indicator used for testing shall be?
1%
5%
10%
Calibrated annually
Enter your name to view your score.
{"name":"Weekly Call Quiz 3-4", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Enhance your understanding of medical gas systems with our comprehensive quiz. Designed for professionals in the healthcare field, this quiz covers essential regulations, safety measures, and technical standards essential for maintaining medical gas systems.Test your knowledge on key topics, including:Check valves and backflow preventionMedical gas piping and intake standardsSafety protocols for cylinder storageMaintenance qualifications and inspection processes","img":"https:/images/course8.png"}
Powered by: Quiz Maker