CAD Quiz 1

When a time error correction is required, PJM receives notification of the time error correction from which of the following?
Time Monitor
RFC
NAESB
NERC
If the PJM ACE calculation is incorrect due to bad data, what would the impact on the AGC function of the EMS?
AGC would stop working.
AGC would continue to operate as desired.
AGC would be sending false signals due to the incorrect ACE.
AGC does not depend on ACE to operate correctly.
Which of the following one-way communication systems is used to disseminate information to MOCs?
All-Call
PJM Messaging System
Radio
EData
What is the PJM cyclic data exchange rate for slow scan data?
4 Seconds
10 Seconds
6 Seconds
2 Seconds
Which of the following PJM tools can be utilized to monitor current and projected system data and emergency procedures information as well as market information?
Data Viewer
EGads
EDART
Markets Gateway
What is the PJM system availability requirement for critical hardware and software?
75%
90%
99.95%
100%
What program would a Generation Owner Operator use to submit generator outages for PJM approval?
EDART
Markets Gateway
EOutage
EMail
For Regulation Market Coordination and Regulation Testing, how soon do members have to submit lists of units to PJM?
2 Business Days
5 Days
1 Week
2 Weeks
When the PJM all-call is received in your control center, which buttons are pushed for the appropriate function?
Press 0 to repeat the message and 3 to acknowledge
Press 1 to repeat the message and 2 to acknowledge
Press 2 to repeat the message and 1 to acknowledge
Press 3 to repeat the message and 2 to acknowledge
The VBUCC system is intended to backup a failure of which of the following?
AC1
AC2
AC1 and AC2
ICCP
The PJM EMS uses what communication protocol?
Analog
XML
ICCP
MPLS
All of the following data is sent from the PJM Control Center to Market Operation Centers EXCEPT:
Regulation Capability
Dispatch Cost
Area Control Error
Regulation Signal
EDART would be used for submitting all of the following information EXCEPT:
IRC Information
LMP Information
AVR Maintenance
Generator Outages
What is the PJM cyclic fata exchange rate for fast scan data?
2 Seconds
4 Seconds
6 Seconds
10 Seconds
{"name":"CAD Quiz 1", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"When a time error correction is required, PJM receives notification of the time error correction from which of the following?, If the PJM ACE calculation is incorrect due to bad data, what would the impact on the AGC function of the EMS?, Which of the following one-way communication systems is used to disseminate information to MOCs?","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}