Electrician Exam 1

Ohm's Law is a relaationship between______.
Voltage, current and power
Voltage, current and resistance
Voltage, current and wattage
Voltage, current and power factor
The amapcity of a conductor is defined by the NEC to be the maximum current, in amperes, a conductor can carry under the conditions of use without exceeding _____.
It's temperature rating
The allowable voltage drop limitations
Its melting point
Its rated voltage
A disconnect switch enclosure installed in a Class II, Division 2 location shall be ____.
Dustight
Heavy duty type
Raintight
General duty type
The interior of enclosures or raceways installed underground shall be considered as a _____location.
Dry
Damp
Hazardous
Wet
Determine the MAXIMUM allowable current-carrying capacity of four (4) size 1/0 AWG THW copper current-carrying conducctors installed in a common raceway with an ambient temperature of 86 deg. F.
150 amperes
105 amperes
112 amperes
120 amperes
The NEC defines a continous load to be a load where the maximum current on the circuit is expected to continue for at LEAST ____ hours or more.
Three
Four
Six
Eight
The service discconecting means for each service shall consist of NOT more than ____switches or circuit breakers.
One
Two
Four
Six
You have determined a conductor has a computed allowable ampacity of 75 ampreres. What is the MAXIMUM standard ampere rating of the overcurrent protection device the NEC permits to protect this circuit where this is not a motor cirucit or part of a multioutlet branch circuit supplying more than one receptacle?
70 amperes
75 amperes
80 amperes
85 amperes
A 208-volt, 3-phase, 50 hp, squirrel-cage, continuous-duty, ac motor has a full-load running current rating of ____.
130 amperes
143 amperes
162 amperes
195 amperes
What is the MAXIMUM distance that a disconnect switch is permitted to be located from the operator's station for a portable carnival ride?
6 feet
10 feet
25 feet
50 feet
Determine the MINIMUM trade size electrical metallic tubing (EMT) required to enclose eight (8) size 6 AWG copper conductors with THHW insulation, when installed in a 50 foot conduit run.
1 in.
1 1/4 in.
1 1/2 in.
2 in.
Where exceptions are not applicable, when a feeder supplies a continous load of 240 amperes, the overcurrent protection device protecting this circuit shall have a rating of at LEAST ____.
240 amperes
300 amperes
250 amperes
275 amperes
Liquidtight flexible metal conduit (LFMC) shall be securely fastened WITHIN ___ of each box or other condiuit termination
4-1/2 ft.
3 ft.
12 in.
18 in.
Where a pull box to be installed will contain conductors of size 4 AWG and larger, and a straight pull of the conductors is to be made, the length of the box shall NOT be less than ____times the trade diameter of the largest conduit entering the box.
Six
Six
Eight
Twelve
 
 
{"name":"Electrician Exam 1", "url":"https://www.quiz-maker.com/QPREVIEW","txt":"Ohm's Law is a relaationship between______., The amapcity of a conductor is defined by the NEC to be the maximum current, in amperes, a conductor can carry under the conditions of use without exceeding _____., A disconnect switch enclosure installed in a Class II, Division 2 location shall be ____.","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}